Power on utilities, 1 initialization – Wasp Bar Code Wasp WPL305 User Manual

Page 10

Advertising
background image

4. Power on Utilities
There are three power-on utilities to set up and test printer hardware.
1. Printer

initialization

2. Ribbon sensor calibration
3. Gap or black mark sensor calibration
Note: You must run the #2 and #3 utilities after running the #1 to properly set
up the printer.

4.1 Initialization
Printer initialization is used to clear DRAM and restore printer settings to
factory defaults. The only one exception is ribbon sensitivity, which will not be
restored to default.

1. Turn the printer power off.
2. Press and hold the FEED button and then turn on the printer.
3. The LED will turn orange, blink red 5 times, blink orange 5 times and then

blink green 5 times. Release after the first green light blink.

4. Printer configuration will be restored to defaults as below after initialization.
WARNING: This will reset all saved settings in the printer.

Parameter Default

setting

Speed

W305, 127 mm/sec (5 ips)

Density 7
Label Width

4.25” (108.0 mm)

Label Height

2.5” (63.4 mm)

Sensor Type

Gap sensor

Gap Setting

0.12” (3.0 mm)

Print Direction

0

Reference Point

0,0 (upper left corner)

Offset 0
Tear Mode

On

Peel off Mode

Off

Cutter Mode

Off

Serial Port Settings

9600 bps, none parity,
8 data bits, 1 stop bit

Code Page

850

Country Code

001

Clear Flash Memory No

8