Installation, Wiring, Operation – White Rodgers 1F51N-619 User Manual

Page 2: Attach subbase to wall, Attach thermostat to subbase

Advertising
background image

2

ATTACH SUBBASE TO WALL

1. Route wires from the cooling equipment to the thermostat

location and pull wires through hole in wall so that 6 inches
of cable protrudes.

2. Pull wires through opening near center of subbase and

connect wires beneath terminal screws as shown under
wiring.

3. Push excess wiring into wall and plug hole with fire-resistant

material (such as fiberglass insulation) to prevent drafts
from affecting thermostat operation.

4. Fasten subbase loosely to wall, as shown, using two mount-

ing screws. Place a level against bottom of subbase, adjust
until level, and then tighten mounting screws to secure
subbase.

ATTACH THERMOSTAT TO SUBBASE

1. Remove cover from thermostat base by gripping the base in

one hand. Use the other hand to pull gently at the top or
bottom of the cover.

2. Carefully remove the shipping protective packing from the

switch.

INSTALLATION

CAPTIVE

SCREW

CAPTIVE

SCREWS

THERMOSTAT

BASE

COVER

MOUNTING SCREWS

SUBBASE

Y

G

W

R

HI

LO

COOL

OFF

VEN

T

COOLING

ANTICIPATOR

THERMOSTAT

SUBBASE

FAN

HI

LO

SYSTEM

OFF

COOL VENT

SUBBASE SWITCH POSITIONS

SYSTEM FUNCTION

FAN

TIMER

RELAY

FAN

SPEED

RELAY

PUMP

RELAY

COMPONENT OPERATION

NO FAN - NO PUMP - NO COOL

COOLING MODE - Pump relay and Fan timer relay energized by
thermostat. Water begins circulating on cooler pads, fan will start
on low speed after short time delay.*

VENT MODE - Fan timer relay energized by thermostat. Fan speed
relay is energized by fan switch in "HI" position. Fan will start on
high speed after short time delay.*

VENT MODE - Fan timer relay energized by thermostat. Fan
will start on low speed after short time delay.*

COOLING MODE - Pump relay and Fan timer relay energized by
thermostat. Fan speed relay is energized by fan switch in "HI"
position. Water begins circulating on cooler pads, fan will start on
high speed after short time delay.*

In "HI" position - No fan, but fan speed relay will
remain energized

Indicates switch position on thermostat subbase and
system function in operation.

* Fan timer relay energizes in approximately one minute. When
system shuts off, relay de-energizes in approximately 1/2 minute.

3. Attach thermostat base to subbase, being sure that all

captive screws are tightened snugly, since they serve as
electrical connections between thermostat and subbase.

4. Snap cover on thermostat base and set temperature lever to

desired setting. The thermostat scale has numbers from 1 to
5. The lower numbers represent cooler temperature and the
higher numbers represent warmer temperature.

WIRING

Take care when securing and routing wires so they
do not short to adjacent terminals or rear of ther-
mostat. Personal injury and/or property damage
may occur.

All wiring should be installed according to local
and national electrical codes and ordinances.

Refer to instruction sheet for 8A18Z-2, Evaporative
Cooler Control for typical system hookup.

OPERATION

The chart below illustrates system and thermostat function during various modes of operation.