CONNECT FILLED LP
TANK

Tank lock
wing nut

ƽ

WARNING: Make sure that the LP tank valve is

closed. Close by turning clockwise.

Hook the LP tank onto the fuel scale. Loosen the tank
lock wing nut. Swing the tank lock down. Tighten the wing
nut. Figure 14.

Figure 14

The hose and regulator are connected in the following
manner:

Slide back the collar of the quick disconnect on the tank
valve. Push the male fitting of the regulator into the quick
disconnect, and maintain pressure. Slide the collar closed.
Figure 15 (a). Figure 15 (b) shows the quick disconnect
engaged and various components of the tank and
regulator. Regulator vent hole should be at 3, 6, or 9
o'clock. It should not be pointed up. Figure 15 (c).

Figure 15

Turn so regulator vent
does not collect water

Hose

Quick disconnect
engaged

Valve handwheel
close clockwise

Tank valve

Collar

Male
fitting

Pressure
relief valve

Tank

Regulator

Regulator
vent

(a)

(b)

(c)

Advertising