Accessories – Windsor Sweeper RRB 360 User Manual

Page 16

Advertising
background image

16

English

Î Check tension, wear and damages on

the V-belt of the sweep roller drive.

Î Check hose at the suction blower for

tightness.

1

Automotive flat plug fuse

2

Pole fuse

Replace the automotive flat plug fuse
with the following rating: 1 A (F2) - vac-
uum pump

Î Replace defective fuse.

Î Replace defective fuse.
Note

A defective pole fuse may only be replaced
by a Windsor service technician or an au-
thorised expert. If this fuse is defective,
check the usage conditions and the entire
control system.

Check suction blower

Replacing the fuse

Pole fuse

Accessories

Side brushes

6.905-626.0

With standard bristles for indoor and out-
door areas.

Standard sweep roll-
er

4.762-430.0

Resistant of wear and moisture. Univer-
sal bristles for inside and outside clean-
ing.

Roller-brush, soft

4.762-442.0

With natural bristles especially for fine
dust sweeping on smooth indoor floors.
Not resistant to wetness; not for abrasive
surfaces.

Dust filter

6.414-576.0

Roller brush, anti-
static

4.762-441.0

Carpet sweeping unit

2.641-665.0

Advertising