MAINTENANCE-SCRUB DECK

86292490 VOYAGER DUO 08/20/07

4-7

SCRUB HEAD

The dual cylindrical scrub head is designed to scrub
chemical into the carpet. The two counter rotating
brushes raise the pile of the carpet, giving it a lush
groomed appearance.

MAINTENANCE

Scrub brushes should be exchanged front to back
every 50 hours to ensure even wear. Scrub brushes
should be replaced as a set when bristle length
wears to height of yellow Perform Alert

TM

bristles.


SCRUB BRUSH REMOVAL

The scrub brushes are removed from the right side
of the machine.


1.
Raise the scrub deck to the storage position.

2.
Pull out on the bottom of the retaining clip.

3.
The brush assembly and end cap should drop

down. Then pull the brush down far enough to
clear the bottom of the housing.


4.
Pull brush out with a rocking motion to free

brush from drive hub.


SCRUB BRUSH REPLACEMENT

1. Lift the drive side of the brush and push it onto

drive hub until a positive stop is felt. The brush
cannot be installed until the brush is fully seated
on the drive hub.


2. Pull out on the bottom of the retaining clip.

3. Line up the end cap with the flats to each side.

4. Slide brush up into the retaining clip until it clicks

in place.