PROBLEM

CAUSE

SOLUTION

Battery disconnected

Check all battery cable connections

Battery cables corroded

Clean connections

No power to machine

Faulty key switch

Replace switch

Low battery charge

Charge batteries

Machine turned on with propel
trigger not in neutral position

Allow pedal to return to neutral.
Restart

Tripped circuit breaker

Reset circuit breaker and check brush

Controller overheated

Allow cool down period

Loose motor connection

Check wires and connections from
controller to motor

Faulty throttle circuit or
potentiometer

Check wires and connections from throttle
to controller and potentiometer resistance

Little or no propel

Faulty brake circuit

Check wires connections

Machine does not change
speeds

Faulty speed control circuit or
potentiometer

Check wires, connections and pot

Forward speed only
Reverse speed only

Faulty forward/reverse switch

Replace switch

Debris caught in scrub brushes

Remove debris

Low scrub brush down pressure

Check brush wear

Poor scrubbing
performance

Low battery charge

Charge batteries

Solution tank empty

Fill solution tank

Solution pump turned off

Turn on pump

Solution strainer plugged

Clean solution strainer

Solution system plumbing
obstructed

Clear obstruction from plumbing

Pump obstructed

Clean or replace pump

Solution solenoid valve obstructed
or stuck

Clean or replace valve

Jet(s) obstructed

Clean or replace jet(s)

Faulty pump circuit or pump

Check wiring, connections, and pump.

Little or no solution flow to
the floor

Faulty solenoid

Check solenoid valve

Circuit breaker(s) tripped

Reset circuit beaker(s) and check brush
pressure.

Low battery charge

Charge battery

Fault brush circuit or motor

Check wires, connections and motor

Brush motors do not run, or
run slowly

Worn brush motor brushes

Replace brushes, check commutator

Actuator circuit breaker tripped

Reset breaker

Scrub deck will not go
down/up

Faulty actuator circuit or actuator

Check wires, connections and actuator

No chemical flow (Deluxe)

Tank(s) empty

Fill with prime chemicals

Chemical pump not primed

Prime chemical pump

Chemical system obstruction

Rinse system with water