Spider/Insect screens

Your Gas Barbecue, as well as any outdoor gas
appliance, is a target for spiders and other insects.
They can nest in the venturi section Venturi(1) of the
burner tubes. This blocks the normal gas flow, and can
cause the gas to flow back out of the air shutter. Figure 5.
This could result in a fire in and around the air shutters,
under the control panel, causing serious damage to
your barbecue.

(1)

We recommend that you inspect the Spider/Insect
screens at least once a year. Also inspect and clean
the Spider/Insect screens if any of the following
symptoms should ever occur.

1. The smell of gas in conjunction with the burner flames

appearing yellow and lazy.

2. Barbecue does not reach temperature.

3. Barbecue heats unevenly.

4. One or more of the burners do not ignite.

ƽ DANGER

Failure to correct these symptoms may
result in a fire which can cause serious
bodily injury or death and cause damage
to property.

GENERAL MAINTENANCE

Inspection and cleaning of the
Spider/Insect screens

To inspect the spider/insect screens, remove the control
panel. If there is dust or dirt on the screens, remove the
burners for cleaning the screens. Refer to Maintenance,
Replacing Main Burners
. Brush the spider/inspect
screens, lightly, with a soft bristle brush (i.e. an old
toothbrush).

ƽ Caution:

Do not clean the spider/insect screens

with hard or sharp tools. Do not dislodge
the spider/insect screens or enlarge the
screen openings.

Lightly tap the burner to get debris and dirt out of the
burner tube. Once the spider/insect screens and burners
are clean replace the burners.

If the spider/insect screen becomes damaged or cannot
be cleaned, call Weber-Stephen Products Customer
Service for replacement parts.

The burner tube air shutter is fitted with a stainless steel
screen(1) to prevent spiders and other insects access to
the burner tubes through the air shutter openings.

Liquid Propane Cylinder requirements

• Replacement LP cylinders supplied by Weber satisfy the

above requirements. Check to be sure other cylinders
have a D.O.T. certification(1), and date tested(2) is within
five years. Your LP gas supplier can do this for you.

If you have questions about spare LP cylinders
contact the Customer Service Representative in your
region using the contact information sheet provided
with your manual.

DOT 4BA240

00/01

(1)

(2)

• All LP tank supply systems must include a collar to

protect the cylinder valve.

• The LP cylinder must be a 20-lb. size (18

1

4

inches high,

12

1

4

inches in diameter).

• The LP cylinder must be constructed and marked in

accordance with the specifications for LP gas cylinders
of the U.S. Department of Transportation (D.O.T.).