INSTALLATION

I N S T R U C T I O N S

INSTALLATION

O P T I O N S

M U L T I P L E C O O K T O P I N S T A L L A T I O N

If the multi-function cooktop is to be used with
any combination of additional cooktop units or
modules with a filler strip, the cut-out width is
calculated by adding the corresponding units'
cut-out dimensions plus 32 mm for each addi-
tional unit. Refer to the illustration below.

IMPORTANT NOTE: When multiple cooktops
and/or modules are installed side by side, each
unit must have its own separate recommended
electrical circuit. When multiple gas cooktops
and/or modules are installed next to one
another, they can receive their gas supply from
a common line.

64 mm

min

FRONT OF COUNTERTOP

489 mm

CUT-OUT

DEPTH

743 mm

TWO MODULES WIDTH

1130 mm

– THREE MODULES WIDTH OR

1124 mm

– 762 mm COOKTOP AND ONE MODULE

1518 mm

– FOUR MODULES WIDTH OR

1511 mm

– 762 mm COOKTOP AND TWO MODULES OR

1276 mm

– 914 mm COOKTOP AND ONE MODULE

356 mm

CUT-OUT

WIDTH

Countertop cut-out dimensions for installation of multiple cooktops
and/or modules

When two or more modules are installed
together, an integrated module filler strip
(IFILLER/S) is recommended. Contact your
Wolf dealer for information on these accessory
components.

IMPORTANT NOTE: Review specific
installation instructions for product to product
capabilities.