A. specifications, Appendix a. specifications – Western Telematic Remote Power Boot Switch User Manual

Page 10

Advertising
background image

Enter Parameters: To define parameters, such as the Location I.D., Power-Up
Default, and Plug Labels, type /P [Enter] and refer to

Section 4

, Step 4.

5.

Set Plugs to Default: To set all plugs to the Power-Up Defaults, type /D [Enter].
Note that if the Default String includes missing or invalid characters, the /D command
will not function.

6.

Exit: To exit from command mode, type /X [Enter].

7.

Note: When the /n ON/OFF/BOOT command is invoked, the port (n) must
be specified by number. The Port Label cannot be used to specify the desired
port.

ON / OFF / BOOT Examples:

To Switch Plug 3 ON, type /3 ON [Enter].

To switch all plugs ON, type /* ON [Enter].

To switch plug 5 OFF, type /5 OFF [Enter].

To switch all plugs OFF, type /* OFF [Enter].

To initiate a boot cycle at Plug 2, type /2 BOOT [Enter].

To initiate a boot cycle at all plugs, type /* BOOT [Enter].

Appendix A. Specifications

Switched Power Plugs: 5 code-selectable AC plugs rated 15 amps max. Each. Total
switched power for all plugs not to exceed 15 amps. Unit initially powers up to ON
condition.

RS232 Port:

DB9 Connector: A 9 Pin Male connector wired in a DTE configuration.

Pin Signal I/O
1

DCD

Carrier Detect

RPB+; Remote Power Boot Switch -- User's Guide

file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (10 of 12) [3/9/2000 5:08:11 PM]

Advertising