CFM are based the cooking appliance output. Wolf suggests 1 CFM per 100 Btu

(.03 kW)

. Additional CFM may be required for long duct runs or

ranges and rangetops with a charbroiler or griddle.

Ventilation Made Easy

10

Step 2: Determine the CFM

The chart below provides CFM specific to the cooking

appliance and ventilation system used. CFM are based on

the cooking appliance output. Wolf suggests 1 CFM per

100 Btu

(.03 kW)

. Additional CFM may be required for long

duct runs and ranges or rangetops with a charbroiler or

griddle.

IMPORTANT NOTE:

Specifing a blower with less CFM than

listed in the chart below will result in decreased airflow

and performance.

When determining the proper CFM for your installation,

take into consideration the equivalent duct length calcu-

lated on the previous page.

IMPORTANT NOTE:

Consult a qualified HVAC professional

for specific applications.

WOLF PRODUCT CFM

COOKTOP HOODS

DOWNDRAFTS

PRO HOODS

MODEL

CFM

CFM

CFM

COOKTOPS AND MODULES

CT15I CT15E CT15G IG15* IS15* IF15* IM15

215

150

215

CT30I CT30IU* CT30E CT30EU* CT30G

450

350

500

CT36I CT36IU* CT36E CT36EU* CT36G

600

500

500

DUAL FUEL RANGES

DF304

500

DF366 DF364C DF364G

900

DF486C DF486G DF484CG DF484DG DF484F

1100

DF606DG DF606F DF606CG DF604CF DF604GF

1500

SEALED BURNER RANGETOPS

SRT304

500

500

SRT366

500

900

SRT364C SRT364G

900

SRT486C SRT486G SRT484CG SRT484DG SRT484F

900

GAS RANGES

R304

500

R366 R364C R364G

900

R488 R486C R486G R484CG R484DG R484F

1100

R606DG R606F R606CG

1500

GAS RANGETOPS

RT366 RT364C RT364G RT362F

900

RT488 RT486C RT486G RT484CG RT484DG RT484F

1100