Ventilation made easy, Step 1: determine the duct run – Wolf Appliance Company 1200 User Manual

Page 9

Advertising
background image

Ventilation Made Easy

9

wolfappliance.com/specs

Step 1: Determine the Duct Run

Determining the equivalent duct length.

Determine the

equivalent duct length for your installation using the

equivalent duct lengths for commonly used ducting. Refer

to the chart on the following page. The equivalent duct

length is calculated as follows:

1)

Compute the length of all straight ducting.

2) Compute the equivalent duct length of all elbows,

transitions and caps.

3) Add equivalent lengths for all sections of the duct run.

EQUIVALENT DUCT LENGTHS

EQUIVALENT

DUCTING

SIZE

LENGTH

QUANTITY

TOTAL

1' (.3 m) STRAIGHT DUCTING

6"

(152)

round

4'

(1.2 m)

8"

(203)

round

1'

(.3 m)

10"

(254)

round

.3'

(.1 m)

3

1

/

4

"

(83)

x 10"

(152)

4'

(1.2 m)

90° ELBOW

6"

(152)

round

24'

(7.3 m)

8"

(203)

round

7'

(2.1 m)

10"

(254)

round

3'

(.9 m)

3

1

/

4

"

(83)

x 10"

(152)

12'

(3.7 m)

45° ELBOW

6"

(152)

round

12'

(3.7 m)

8"

(203)

round

4'

(1.2 m)

10"

(254)

round

2'

(.6 m)

3

1

/

4

"

(83)

x 10"

(152)

8'

(2.4 m)

ROUND TO RECTANGULAR TRANSITION

6"

(152)

round to 3

1

/

4

"

(83)

x 10"

(152)

5'

(1.5 m)

8"

(203)

round to 3

1

/

4

"

(83)

x 10"

(152)

1'

(.3 m)

3

1

/

4

"

(83)

x 10"

(152)

to 6"

(152)

round

12'

(3.7 m)

3

1

/

4

"

(83)

x 10"

(152)

to 8"

(203)

round

16'

(4.9 m)

ROUND TO ROUND TRANSITION

6"

(152)

round to 8"

(203)

round

4'

(1.2 m)

8"

(203)

round to 10"

(254)

round

1'

(.3 m)

8"

(203)

round to 6"

(152)

round

12'

(3.7 m)

10"

(254)

round to 8"

(203)

round

3'

(.9 m)

ROOF CAP OR WALL CAP

6"

(152)

round

60'

(18.3 m)

8"

(203)

round

20'

(6.1 m)

10"

(254)

round

9'

(2.7 m)

3

1

/

4

"

(83)

x 10"

(152)

60'

(18.3 m)

TOTAL

Advertising
This manual is related to the following products: