Wolf Cooktop Ventilation Hoods

HOOD PLACEMENT

Installation of the cooktop wall or island hood should be

24"

(610)

to 30"

(762)

from the bottom of the hood to the

countertop. To determine placement of the cooktop hood,

you must calculate the height of the telescopic chimney

flue. The minimum and maximum flue extension for each

cooktop hood is listed in the charts below.

IMPORTANT NOTE:

Both sections of the telescopic

chimney flue must be installed in order for the chimney to

be lifted for service.

Wolf Cooktop Ventilation

15

wolfappliance.com/specs

B

A

C

D

MINIMUM

FLUE

EXTENSION

Cooktop hood placement.

Cooktop Chimney Hoods

FLUE EXTENSION

MINIMUM

MAXIMUM

CTWH30

30

1

/

2

"

(775)

48

1

/

2

"

(1232)

CTWH36

32

5

/

8

"

(829)

50

7

/

8

"

(1292)

IH4227

33

1

/

2

"

(851)

47"

(1194)

Cooktop Low-Profile Hoods

FLUE EXTENSION

MINIMUM

MAXIMUM

CTEWH30I

29

1

/

8

"

(740)

41

1

/

2

"

(1054)

CTEWH36(I)

29

1

/

8

"

(740)

41

1

/

2

"

(1054)

CTEWH45(I)

29

1

/

8

"

(740)

41

1

/

2

"

(1054)

CTEIH42I

28

1

/

4

"

(718)

41

1

/

2

"

(1054)

CALCULATE CHIMNEY FLUE HEIGHT

A) Height from finished floor to finished ceiling. 8'

(2.4 m)

or 9'

(2.7 m)

ceilings are typical.

B) Height from finished floor to countertop. A 36"

(914)

countertop height is standard.

C) Hood mounting height (bottom of hood to countertop).

Dimension C must be between 24"

(610)

and 30"

(762)

.

8'

(2.4 m)

ceilings may not allow the maximum 30"

(762)

hood mounting height.

D) Calculate chimney flue height: D = A – (B + C).

Dimension D must be between the minimum and

maximum flue extension listed in the charts. Refer to

the illustration below.