MAINTENANCE


CAUTION: Before starting any maintenance or cleaning jobs, the compressor

has to be switched off and disconnected from the power supply!

ƒ Make sure the compressor accessories and air tools are relieved from pressure.
ƒ Be sure that all safety and protection devices are operational after having

finishing maintenance or cleaning jobs.

ƒ Take care to remove all service tools from the compressor before starting to work

again.

ƒ Other maintenance jobs than described in this manual have to be done by an

authorized service center.

After approx. 30 hours operating time:


ƒ Drain pressure tank. Turn drain valve at the bottom of the tank counterclockwise,

until compressed air will escape. Any condensed water will be exhausted at the
same time.

ƒ Inspect air filter and air vents. Remove any material that my have gotten stuck in

the are vents.

ƒ Clean the exterior of the compressor. Wipe off any dirt or dust that has

accumulated on the air tank and housing.

Every month


ƒ Check the safety valve for leaks or dirt. If necessary clean or replace.

Every 2 months

ƒ Clean air filter. First take off the motor housing from the air compressor. This is

done by unscrewing the 2 hex bolts on the top of the housing. Then screw the air
filter off the compressor using a wrench # ½ “. (see FIG. 7 and FIG. 8) Rinse the
air filter in AIR TOOL OIL, than blow out any dust that may still remain and dry

thoroughly. Replace filter in reverse order.

FIG. 7

FIG. 8