weber 5000 Series User Manual

Page 40

Advertising
background image

40

40

h) Lift and twist the burner assembly slightly, to
separate the crossover tube from the burners.
Figure 19. Remove the burners from the cooking

box.

i)

To reinstall burners, reverse steps c) through h).

Crossover tube

Figure 19

d) Unlatch the Spider Stopper Guards and remove.

Figure 16.

e) Use an adjustable wrench to remove the

thermocouple from the FlameCheck valve.

f)

Remove the manifold bracket and unscrew the two
wing nuts that hold the manifold to the cooking
box. Pull the manifold and valve assembly out of the
burners and carefully set it down. Figure 17.

g) Slide the burner assembly out from under the guide

screw and washer in the corners of the cooking box.
Figure 18.

Figure 16

View from behind
cooking box

Wing nuts

Figure 17

Guide screw

Figure 18

ƽ CAUTION: The burner openings must be
positioned properly over the valve orifices.
Figure 20a.

Check proper assembly before fastening manifold in
place. Figure 20b.

Figure 20

Valve

Burner

(a)

(b)

Advertising