Electrical, Installation, Warning – Wayne Jet Pump Water Systems Shallow Well User Manual

Page 4: Caution

Advertising
background image

(A) MANANTIAL:

Un manantial que emerge

de la tierra. Ocurre cuando

el agua en materiales

permeables está atrapada

entre materiales

impermeables tales como

roca o arcilla.

(B) LAGO, ARROYO o EST

ANQUE:

Agua superficial, que a menos

que sea tratada, por lo general

no es apta para consumo

humano. Puede ser utilizada

para fines tales como lavado

o irrigación.

(C) POZO EXCA

V

ADO:

Se excava un hoyo de

varios pies de diámetro

hasta una profundidad

basante superficial.

Luego se reviste con

ladrillo, piedra o

concreto para evitar

que se derrumbe.

(D) POZO ACCIONADO:

Se acciona una tubería

con una pantalla con

punta en la tierra, por

debajo de la capa

freática. La profundidad

por lo general es menor

a 15,25 m (50 pies).

Los diámetros comunes

fluctúan entre 2,5 cm (1")

y 5,1 cm (2")

(E) POZO PERFORADO:

Un hoyo perforado en

la tierra con maquinaria y

revestido con tuberías.

Las profundidades

fluctúan entre algunos

pies hasta más de 305 m

(1000 pies). Los diámetros

comunes son 5,1 cm (2"),

7,6 cm (3"), 10,2 cm (4") y

15,2 cm (6") para pozos

de agua de uso doméstico.

(F) CISTERNA:

Un tanque subterráneo

construido para recolectar

agua de lluvias de los

techos. El agua no es

apta para consumo

humano.

(A) MANANTIAL

(B) LAGO,

ARROYO,

EST

ANQUE

(C) POZO EXCA

V

ADO

(D) POZO

ACCIONADO

(E) POZO

PERFORADO

(F) CISTERNA

MA

TERIAL

PERMEABLE

ARENA

ACUIFERA

CAP

A FREA

TICA

ESQUISTO

TIERRA

SUPERFICIAL

ARCILLA

Suministr

os de Agua

Figura 13 - Suministros de Agua

29 Sp

Manual de instrucciones de operación y piezas

Modelos para pozos profundos

noise transmitted to the house
thrugh the piping.

4. Provide a hose bib (faucet) at the

lowest point in the system to drain
the system for service or storage.

SHALLOW WELL PUMP WITH
PRECHARGED STORAGE TANK
(FIGURE 6)

1. Shut off the power to the pump.

2. Open the faucet nearest the tank

and allow all water to drain from
the tank.

3. Measure the tank precharge at the

valve stem using a tire pressure
gauge.

4

4. If necessary, precharge with an air

pump to 28 - 30 psi on 1/2, 3/4 and 1
HP pumps.

5. Slope the horizontal pipes upward

toward the pump to prevent
trapping air. If the horizontal
distance exceeds 25 feet, see Chart
2 for the recommended pipe size.

Electrical

Risk of electrical
shock. This pump is

designed for indoor installation only.

The voltage of power supply must
match the voltage of the pump. All
above ground well pumps except
SWS50BOOST have dual voltage motors
preset at the factory to 230 volts. The
motors can be converted to 115 volts
by turning the voltage selector to the
desired voltage (See Figure 7). Use a
needle nose pliers to pull the selector
out approximately 1/4”, rotate and
then reinsert in correct position.

Select the proper size wire and fuse
(Chart 3). Time delay fuses are
recommended over standard fuses for
motor circuit protection. All pump
motors have built-in automatic
overload protection that will prevent
damage to the motor due to
overheating.

Do not connect to
electric power

supply until unit is permanently
grounded. Connect ground wire to
approved ground then connect terminal
provided.

A metal underground water pipe or
well casing at least 10 feet long makes
the best ground electrode. If plastic
pipe or insulated fittings are used, run

!

WARNING

!

WARNING

Installation

(Continued)

NOTE: A packer type foot valve can be
installed in the well (Figure 3,
Illustration B). This type of foot valve
allows the well to be filled with water
when priming and makes the inlet pipe
much easier to test for leaks. Follow
the manufacturer’s instructions when
installing the packer type foot valve.

As an alternative, an in-line check valve
can be used with a driven well (Figure
3, Illustration C). The pipe between the
check valve and the water level will
always be under a vacuum.

Leaking joints or couplings will allow
air to leak into the pipe and cause
abnormal pump operation. Make sure
to use pipe joint compound on all male
pipe threads.

DUG WELL, CISTERN, LAKE AND SPRING
INSTALLATION (FIGURE 12)

1. Install a foot valve on inlet pipe and

lower into water.

The foot valve
should be at least

18” from the bottom of the well or
sand or sediment could be drawn into
the system.

NOTE: When a lake is used as a water
supply, make sure the inlet pipe is deep
enough to be submerged at all times.
Slope the horizontal piping upward
toward the pump to prevent trapping
air. The pipe must be removed during
winter months or protected against
freezing.

Protect the pipe from damage from
swimmers and boats.

Install a screen

around the inlet

pipe to prevent the entrapment of
swimmers.

SHALLOW WELL PUMP WITH
CONVENTIONAL STORAGE TANK
(FIGURES 4 & 5)

1. Install air volume control on tank.

2. Connect the copper tube from the

air volume control to the
uppermost 1/8” NPT opening on the
side of pump. Be sure the
connections are tight. Leaking can
cause the pump not to prime.

3. Install a valve and an isolator hose

between the tank and the house
plumbing to aid in pump removal
for servicing and for reducing the

!

WARNING

!

CAUTION

Operating Instructions and Parts Manual

Shallow Well Jet Pump

Figure 4 - Horizontal Tank

Air
Volume
Control
Tubing

Pressure
Switch

Prime
Plug

Air

Volume
Control

Figure 5 - Vertical Tank

Air

Volume
Control

Outlet

Air Volume

Control

Tubing

Hose

Coupling

Figure 6 - Precharged Storage Tank

28-30 psi

3/4 HP & 1 HP

Motor

www.waynewatersystems.com

Outlet

Priming
Plug

Nozzle
Clean
Out

Drain
Fitting

115 V

230 V

115 V

230 V

Figure 7 - Voltage Selector