Fryer Module Specifications

4

1

/

2

"

(13)

SIDES

1"

(25)

FRONT / BACK

7

1

/

2

"

(191)

6"

(152)

DRAIN

OUTLET

21"

(533)

15"

(381)

Overall Dimensions

FRYER MODULE

Installation Specifications

IMPORTANT NOTE:

Installation of the Wolf electric fryer

module must meet minimum clearance requirements

shown in the installation illustration on page 6.

The fryer module is designed to fit a standard 24" (610)

deep base cabinet with 25" (635) deep countertop. Before

making the countertop cut-out, verify that the module will

clear the side walls of the base cabinet below.

It is recommended that you use a Wolf cooktop ventilation

hood, pro hood or hood liner with the fryer module. Refer

to the Wolf design guide.

IMPORTANT NOTE:

Wolf does not recommend the use of

downdraft ventilation with the fryer module.

MANUAL DRAIN OUTLET

IMPORTANT NOTE:

The fryer module must be installed in

a base cabinet that allows access to the manual drain

valve for draining the oil. A heat-resistant bucket must be

positioned under the drain outlet to accept the oil. The

bucket must have a minimum 2 gallon (7.6 L) capacity.

Refer to the installation illustration on page 6 for location

of the manual drain outlet.

Failure to locate the fryer module without the proper

clearances will result in a fire hazard.

The fryer module is intended for indoor use.