8

PROGRAMMING

TROUBLESHOOTING

Comfort Alert Codes
The Comfort Alert diagnostics product monitors the air
conditioning outdoor systems with single phase Copeland
Scroll compressors. Abnormal system and electrical
conditions are indicated by flashing ALERT codes on the
yellow LED on the Comfort Alert module. The flash codes are
transmitted to the thermostat by the Comfort Alert Thermostat
interface module. The Comfort Alert compatible thermostat
displays

“Call For Service” that flashes at the same rate as

the yellow LED on the Comfort Alert module.

Comfort Alert Yellow Alert Codes

1 Flash

Long run time

2 Flashs

System pressure trip

3 Flashs

Short cycling

4 Flashs

Locked rotor

5 Flashs

Open circuit

6 Flashs

Open start circuit

7 Flashs

Open run circuit

8 Flashs

Welded Contactor

9 Flashs

Low voltage

Planning Your Program – Important

The Heating and Cooling Program schedules below allow you
to pencil in your own program times and temperatures.
The 1F85-0422 comes configured for 5/1/1 day programming
and can also be configured for 5/2 day programming (see
configuration section).
Factory settings are listed on Monday through Friday, Satur-
day and Sunday. If you are re-programming a 5/2 day sched-
ule, pencil in your own times and temperatures directly below
the factory times and temperatures.

If you are re-programming a 5+1+1 fill in all lines with the
times and temperatures you want.
Keep the following guidelines in mind when planning your
program.
• In Heating, lower temperatures will save energy.
• In Cooling, higher temperatures will save energy.
• If you plan on using Auto Changeover, do not program
the heating higher than the cooling.

Worksheet for Re-Programming 5/2 Day and 5+1+1 Day Program

Heating

Program

Wake Up

(Period 1)

Leave For Work

(Period 2)

Return Home

(Period 3)

Go To Bed

(Period 4)

Mon-Fri

6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F

Sat-Sun

or Sat

6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F

Sun

5+1+1 only

6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F

Cooling

Program

Wake Up

(Period 1)

Leave For Work

(Period 2)

Return Home

(Period 3)

Go To Bed

(Period 4)

Mon-Fri

6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F

Sat-Sun

or Sat

6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F

Sun

5+1+1 only

6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F