White Rodgers 1F80-0224 User Manual

Applications, Specifications, Precautions

Advertising
background image

This thermostat is intended for use with a low voltage NEC
Class II system. Do not use this thermostat with a line voltage
system. If in doubt about whether your wiring is millivolt, line,
or low voltage, have it inspected by a qualifi ed heating and air
conditioning contractor or electrician.

Do not exceed the specifi cation ratings.

All wiring must conform to local and national electrical codes
and ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could
cause the control to malfunction.

Blue 2” Single Stage Thermostat

Installation and Operating Instructions

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.

APPLICATIONS

For use with the following Class II systems:
• Single

Stage

systems

Single-stage heat pump systems with no Aux heat

DO NOT USE WITH:

Systems exceeding 30 VAC and 1.5 amps

3-wire zoned hydronic heating systems

1F80-0224 Thermostat

Model

Programming Choices

1F80-0224

24-hour Programmable

SPECIFICATIONS

Electrical Rating:

Battery Power ................................................. mV to 30 VAC, 50/60 Hz or DC

Input-Hardwire ................................................ 20 to 30 VAC

Terminal Load ........................................................ 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ...................................................... 45° to 90°F (7° to 32°C)
Differential (Single Stage) ...................................... Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) ........................................ Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient ................................................. 32° to +105°F (0° to +41°C)
Operating Humidity ................................................ 90% non-condensing max.
Shipping Temperature Range ................................ -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ......................................... 3-3/4”H x 4-3/4”W x 1-1/2”D

PRECAUTIONS

To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

CAUTION

!

Do not use on circuits exceeding specifi ed voltage.
Higher voltage will damage control and could cause
shock or fi re hazard.

Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.

Thermostat installation and all components of the
system shall conform to Class II (current limited)
circuits per the NEC code. Failure to do so could cause
a fi re hazard.

WARNING

!

www.white-rodgers.com

PART NO. 37-7014B

Replaces 37-7014A

0924