86039100 p4-14, Machine troubleshooting – Windsor Walk Behind Scrubber SCX326 User Manual

Page 32

Advertising
background image

MACHINE TROUBLESHOOTING

CUTTER 36V 86039100 05/01/07

4-14

PROBLEM

CAUSE

SOLUTION

Little or no solution flow to the floor

Solution tank empty

Fill solution tank

Solution flow turned off or
set too low

Turn on or increase flow
setting

Solution strainer plugged

Clean solution strainer

Solution hoses obstructed

Clear obstruction from
hose

Solution solenoid valve
obstructed or stuck

Clean or replace

Vent hole in solution tank
lid obstructed

Clear obstruction from vent
hole

No power to machine

Battery disconnected

Check all battery cable
connections

Emergency shut-off
activated (If included)

Reset

Battery connections
corroded

Clean connections

Faulty main contactor

Replace contactor

Faulty key switch

Replace switch

Little or no propel

Low battery charge

Charge batteries

Wheels spin

Decrease brush pressure

Controller overheated

Allow cool down period
Adjust brush shroud if
needed

Loose connection

Check motor wires and
connection

Advertising
This manual is related to the following products: