Silent sump system, 2description, Unpacking – Wayne 550100-001 User Manual

Page 2: Assembly, Installation & set-up

Advertising
background image

2

DESCRIPTION

JOB-READY SILENT SUMP SYSTEM

This job ready sump pump system includes all the necessary
components required for direct system replacement and is
an automatic pump used to remove ground water from sump
pits. The most common application is for basement drainage
to prevent fl ooding in residential buildings. It is designed to
pump clear water only.

UNPACKING

Inspect your pump. Occasionally, products are damaged
during shipment. If the unit is damaged, return the unit to the
place of purchase for replacement.

This system should contain the following components:

• Sump pump

• 1-1/2 inch PVC piping

• Flood Alert™ wireless sump • PVC coupler
pump monitoring system (with clamps)
• Silent Check Valve

• Instruction Manuals (2)

READ & FOLLOW ALL INSTRUCTIONS OF ALL PROVIDED MANUALS

SAVE THESE INSTRUCTIONS — DO NOT DISCARD

ASSEMBLY

This system includes 1-1/2 inch
diameter piping. Any existing
plumbing other than 1-1/2 inch
will require an additional adapter
(not included).

1) Before modifying existing

sump plumbing, fully
assemble the silent sump
system. A fl at-head
screwdriver, PVC cement, and
PVC primer will be needed to
complete the assembly.

Read all

directions and

precautions on the PVC cement
and primer containers before
making the joint. Do not allow
PVC cement to come in contact
with inner workings of the
check valve.

2) Using PVC Cement and

Primer (both sold separately)
join the inlet side of the check
valve with the pre-installed
PVC discharge pipe. (Fig. 1).

NOTE: Raised lettering on

the check valve indicates the
direction of water fl ow

www.waynepumps.com

INSTALLATION GUIDE

SILENT SUMP SYSTEM

Please read and save these instructions. This manual contains important Safety Warnings and Operating Instructions. You will need to refer to it
before attempting any installation or maintenance. Always keep this manual with the unit so that it will be easily accessible. Failure to read and follow
these warnings and instructions could result in property damage, serious injury or death.

3) Next, attach the Flood Alert

wireless monitoring system

fl oat bracket directly below the silent check valve using
the included plastic zip-ties (Figure 2).

NOTE: Attach sump alarm fl oat to bracket when system is

connected to existing plumbing. See installation and set-up.

INSTALLATION & SET-UP

1) With the assembled silent

sump system as a height
reference, modify existing
plumbing to conform to
the silent sump system’s
overall height.

2) Using the provided rubber

PVC coupler and two
stainless steel clamps,
attach silent sump
discharge to existing
discharge plumbing
(Figure 3).

3) Attach the Flood Alert

fl oat switch to the
previously installed fl oat
bracket (Figure 4).

4) Refer to the wireless

sump pump monitoring
system manual for proper
transmitter placement.

5) Finish installation and

testing of the wireless
sump pump monitoring
system by using the
provided instruction
manual.

6) Refer to provided manuals for further installation testing

and troubleshooting.

7) After installation, check the system to ensure it is

operating properly.

To order a replacement check valve,
please call WAYNE at: 1-800-237-0987

Order part number 28211-002 for the check valve.

For additional replacement parts, refer to the provided
manuals for availability.

1

2

4

3

Existing
plumbing