Wcp85 – Wayne WCP85 User Manual

Page 5

Advertising
background image

5

WCP85

Troubleshooting Chart

Pump may start unexpectedly. Disconnect power supply before ser vic ing.

Symptom

Possible Cause(s)

Corrective Action

Pump fails to run

Pump emits loud noises
when operating

Pump operates but
there is no flow of
liquid

Liquid drains back into
pump from discharge
line

Liquid leaks from
around check valve

1. Pump not plugged in
2. Low voltage, blown fuse, open

circuit

3. Reservoir is absent of

condensate

4. Drain/discharge lines blocked

Foreign material in reservoir

1. Float is sticking
2. Discharge height greater than

15 feet

3. Obstruction in discharge tube
4. Blockage in check valve
5. Damaged check valve

1. Damaged check valve
2. Blockage in check valve
3. Discharge line is 5’ or less

1. Check valve fastened too tight

or too loose

2. Damage to O-ring

1. Plug in.
2. Have a certified electrician check fuse circuit.

3. Make sure that there is adequate condensate level in

reservoir. Check drain lines and/or discharge line for
obstructions.

4. Check drain lines and/or discharge line for obstructions.

Refer to Maintenance section for cleaning instructions.

1. Refer to Maintenance section for cleaning instructions.
2. Measure from bottom of pump to highest point. Rework

discharge if height is greater than 15’. Refer to Installation
Step 4 for instructions.

3. Check discharge line for blockage. Remove debris.
4. Refer to Maintenance section for cleaning instructions.
5. Contact Wayne.

1. Contact Wayne.
2. Refer to Maintenance section for cleaning instructions.
3. Condensate liquid may drain out of line into reservoir due

to discharge height. This is normal. No action is necessary.

1. Check valve should be hand-tightened, then tightened an

additional 1/2 turn with a 9/16” wrench.

2. Replace with a 1/2” ID x 11/16” OD x 3/32” thick O-ring or

contact Wayne Technical Service at 1-800-237-0987.

Before servicing a pump, always shut off the main power breaker and then unplug the pump.
Make sure you are not standing in water. Make sure you are wearing insulated, protective-

soled shoes. Under flooded conditions, check your local electric company or a qualified licensed electrician for
disconnecting electrical service prior to pump removal. If the above checklist does not solve the problem, contact
Wayne Technical Service at 1-800-237-0987.