Troubleshooting chart, Eeaup250 – Wayne EEAUP250 User Manual

Page 3

Advertising
background image

3

www.waynepumps.com

EEAUP250

7. If pump runs continuously, unplug the unit. Once unplugged,

check for debris stuck inside the sensor body (Figure 3).
Remove any trapped leaves, debris or dirt.

8. If the pump cycles on and off too often the electronic switch may

need cleaning. Unplug the pump and turn upside down. The
sensor probe will be visible inside the switch housing. Clean inside
the housing gently scrubbing with a small brush using soapy water.

MAINTENANCE AND TROUBLESHOOTING
(CONTINUED)

Figure 3 - Remove Debris From Sensor

CLEAN DEBRIS

INSIDE SENSOR

PRIMING HOLE

BASE SCREWS (4)

INLET SCREEN/

BASE

IMPELLER PLATE

Figure 2 - Priming Hole Location

WHEN REATTACHING THE BASE (INLET SCREEN), BE SURE THAT THE

FOUR (4) "PLUGGED" SCREENS ARE ORIENTED BELOW THE SWITCH.

Do not use pump if any part of the switch

housing or probe is cracked, broken or missing.

PUMPING HEIGHT
When water is pumped to an elevated position, any volume that has
not reached the discharge outlet can flow back through the pump
when the pump shuts off. This back-flow can cause the water level
in small areas to rise enough to re-start the pump. A check valve
[Check Valve Sold Separately] is required in this situation. For proper
operation, make certain the check valve is oriented as instructed.

In small areas a check valve is required to prevent

backfl ow. Without a check valve the pump may

cycle continuously and potentially wear out the pump components.

Troubleshooting
Chart

Electrocution Hazard! Pump starts automatically. Disconnect the power before

attempting any repairs. Failure to follow will result in serious injury or death.

Symptom

Possible Cause(s)

Corrective Action

Pump will not
start or run

1. Tripped home electrical breaker
2. GFCI tripped
3. Low line voltage
4. Defective motor
5. Dirty switch
6. Impeller obstructed

7. Inlet screen clogged
8. Priming hole plugged

1. Reset breaker
2. Check for damaged wiring or moisture
3. If voltage is under 108 volts, check wiring size
4. Replace pump
5. Rinse out switch with clean water (Figure 3 on page 3)
6. Remove base and impeller plate (Figure 2 on page 3) check for

debris; clean

7. Clean inlet screen (Figure 2 on page 3)
8. Clean hole, inside volute housing, with a pin or paper clip (Figure

2 on page 3)

Pump starts and
stops too often

1. Backflow of water from piping
2. Dirty switch
3. Priming hole plugged

1. Install or replace check valve [Sold Separately: CAT No. 40138]
2. Rinse out switch with clean water (Figure 3 on page 3)
3. Clean hole, inside volute housing, with a pin or paper clip

(Figure 2 on page 3)

Pump will not
shut off or runs
continuously

1. Debris in switch
2. Discharge height exceeds capability

1. Rinse out switch with clean water (Figure 3 on page 3)
2. Raise pump or reduce discharge height

Pump operates
but delivers little
or no water

1. Impeller obstructed

2. Priming hole plugged

3. Obstructed piping
4. Discharge height exceeds capability

1. Remove base and impeller plate (Figure 2 on page 3), check for

debris; clean

2. Clean hole, inside volute housing, with a pin or paper clip

(Figure 2 on page 3)

3. Check for kinks, reposition hose or check for debris
4. Reposition pump to reduce discharge height