TROUBLESHOOTING.
86038450 04/12/07
4-5ENG
PROBLEM CAUSE
SOLUTION
Drive controls cont.
Faulty motor.
Squeeze the control lever and test the voltage at U (wire 
#27 & 28). When the output voltage varies with the 
control lever but the motor does not respond and all the 
tests above have been done, replace the motor. 
Loose Connection.
With main power on, test voltage at terminal 30 (X) on 
Relay should be 34 to 38 VDC. With switch on, check 
voltage to wire side of resistor (Y). Should be 34 to 38 
VDC. 
Bad Relay.
With main power on, test voltage at terminal 87 (Z) 
should be 34 to 38 VDC. 
Machine will not propel
Faulty Resistor.
With main power on, test voltage at terminal 85 (AA) 
should be 22 to 26 VDC. 