MACHINE OPERATION
86038450 04/12/07
3-2ENG
 
PRE-RUN MACHINE INSPECTION 
1. Disconnect the battery charger. (See battery 
charging procedure).
2. Close the cover. 
3. To raise the deck: Turn on the main power 
switch and press the burnishing head switch.
4. Turn or install a new burnishing pad as needed.
NOTE: Pad lock has left hand threads. To 
loosen turn clockwise. 
 
 
 
 
 
 
 
 
 
 
 
5. Check wheels and other pivot points for proper 
lubrication.
 
OPERATING THE MACHINE 
1. If using a machine that is already set up, check 
to make sure the pad is properly installed.
2. Adjust the operating control handle to a
comfortable position using the handle lock lever.
3. Turn on the main power switch. 
4. Lower or raise deck by pressing burnishing head 
switch.
5. The pad motor will only run when the burnishing
head is lowered to within 3 inches of the floor.
6. The drive controls are shown on page 3-1. 
7. The pad pressure is adjusted using the knob at 
center of panel. The operator monitors the amp 
draw using the meter located on the control 
panel and ensures that the needle remains in 
the “green” operating 
range. (See page 3-1, #4 & 11). 
 
 
 
To prevent possible damage to the floor surface, 
always keep the machine moving while the pad 
is spinning. 
 
8. When the pad motor switch bar is squeezed, the 
pad motor runs.
 
9. Return the machine to the battery charger when 
the battery light indicator light is amber. Do not 
operate machine when indicator is flashing red. 
 
 
 
FILTER BAG 
The filter bag is accessed under the cover. 
 
DUST CONTROL SKIRT 
Replace skirt (86007290 – PRV NO. 730017) when 
worn, torn, or damaged in any way that allows dust 
to escape.