White Rodgers 1F85-0477 User Manual

Applications specifications, Caution

Advertising
background image

1

Blue 4” Universal Thermostat with

Automatic Heat/Cool Changeover Option

Single Stage, Multi-Stage or Heat Pump

Installation and Operating Instructions for Model:

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING
THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.

Save these instructions for future use!

APPLICATIONS

SPECIFICATIONS

Electrical Rating:

Battery Power .................................................... mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire ................................................... 20 to 30 VAC

Terminal Load ........................................................... 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ......................................................... 45° to 90°F (7° to 32°C)
Differential (Single Stage) ......................................... Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) ........................................... Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient .................................................... 32° to +105°F (0° to +41°C)
Operating Humidity ................................................... 90% non-condensing max.
Shipping Temperature Range ................................... -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ............................................ 3-7/8”H x 5-1/8”W x 1-1/4”D

www.white-rodgers.com

www.emersonclimate.com

1F85-0477 Thermostat

Model

Programming Choices

1F85-0477

7 Day

5/1/1 Day

ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this product
may replace a product that contains mercury.

Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any spilled
mercury and place in a sealed container. For proper disposal
of a product containing mercury or a sealed container. Refer
to

www.white-rodgers.com for location to send product

containing mercury.

To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

CAUTION

!

THERMOSTAT APPLICATION GUIDE

Description
Heat Pump (No Aux. or Emergency Heat)

Yes

Heat Pump (with Aux. or Emergency Heat)

Yes

Systems with up to 2 Stages Heat, 2 Stages Cool

Yes

Heat Only Systems (with optional fan switch)

Yes

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

Cool Only Systems

Yes

Gas or Oil Heat

Yes

Electric Furnace

Yes

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

Index

Page

Installation

2

Wiring Connections

2

Wiring Diagrams

3

Thermostat Quick Reference

5

Installer Configuration Menu

6

Operating Your Thermostat

8

Programming

9

Troubleshooting

10

PART NO. 37-7050B

Replaces 37-7050A

1011