Troubleshooting, Roubleshooting, Ange does not work – Whirlpool 8053373A User Manual

Page 26: Broiler burner, Urface burners

Advertising
background image

26

CAUSE

The range is not plugged into a properly grounded outlet (120v polarized).

The range is not properly connected to the gas supply. Contact a designated
service technician to reconnect the range to the gas supply. (See the
Installation Instructions.)

You have blown a household fuse or tripped a circuit breaker.

T

ROUBLESHOOTING

Most cooking problems often are caused by little things you can find and fix without tools of any
kind. Check the lists below and on the next page before calling for assistance or service. If you
still need help, see “Requesting Assistance or Service” on page 28.

R

ANGE DOES NOT WORK

PROBLEM

Nothing works

O

VEN

/

BROILER BURNER

PROBLEM

The oven does not work

The burner fails to light

The burner flames lift
away from the ports, are
yellow, or are noisy

CAUSE

You have not set the electronic control correctly. Refer to setting the
electronic oven control section. (See pages 10 to 18.)

You have set a delayed start time. Wait for the start time to be reached or
cancel and reset the control.

The main or regulator gas shutoff valve is in the off position. (See the
Installation Instructions.)

The ignitor is broken. Contact a designated service technician to replace it.

You have blown a household fuse or tripped a circuit breaker.

The air/gas mixture is incorrect. Contact a designated service technician to
check the air/gas mixture or see the Installation Instructions.

S

URFACE BURNERS

CAUSE

The control knob is not set correctly. Push in the control knobs before turning
them. Make sure the control knob is turned to the Light position. (See page 6.)

You have blown a household fuse or tripped a circuit breaker.

The burner ports may be clogged. Clean them with a straight pin. (See page 22.)

The burner ports may be clogged. Clean them with a straight pin. (See page 22.)

The burner caps may not be positioned properly. (See page 22.)

The burner needs cleaning. (See pages 21 and 22.)

The air/gas mixture is incorrect. Contact a designated service technician to
check the air/gas mixture or see the Installation Instructions.

The burner is wet from washing. Let it dry.

PROBLEM

The burner fails to light

The burner flames are
uneven

The burner flames lift off
the ports, are yellow, or
are noisy when turned off

The burner makes a
popping noise when on

Advertising