White Rodgers BLUE 2 1F89-0211 User Manual

Applications, Specifications, Precautions

Advertising
background image

1

Blue 2” Heat Pump Thermostat

Heat Pump or Single Stage

Installation and Operating Instructions

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.

APPLICATIONS

1F89-0211 Thermostat

Model

Programming Choices

1F89-0211

Non-Programmable

SPECIFICATIONS

Electrical Rating:

Battery Power ................................................. mV to 30 VAC, 50/60 Hz or DC

Input-Hardwire ................................................ 20 to 30 VAC

Terminal Load ........................................................ 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ...................................................... 45° to 90°F (7° to 32°C)
Differential (Single Stage) ...................................... Heat 0.8°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) ........................................ Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient ................................................. 32° to +105°F (0° to +41°C)
Operating Humidity ................................................ 90% non-condensing max.
Shipping Temperature Range ................................ -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ......................................... 3-3/4”H x 4-3/4”W x 1-1/2”D

PRECAUTIONS

To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

CAUTION

!

Do not use on circuits exceeding specifi ed voltage.
Higher voltage will damage control and could cause
shock or fi re hazard.

Thermostat installation and all components of the
system shall conform to Class II (current limited)
circuits per the NEC code. Failure to do so could cause
a fi re hazard.

WARNING

!

PART NO. 37-6997C

Replaces 37-6997B

0932

www.white-rodgers.com

YOUR THERMOSTAT REPLACES

Description
Heat Pump (No Aux. or Emergency Heat)

Yes

Heat Pump (with 1 Aux. or Emergency Heat Stage)

Yes

Standard Heat & Cooling Systems

Yes

Two Stage Heat & Two Stage Cool

No

Standard Heat Only Systems

Yes

Millivolt Heat Only Systems - Floor or Wall Furnaces

Yes

Standard Central Air Conditioning

Yes

Gas or Oil Heat

Yes

Electric Furnace

Yes

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

Hydronic (Hot Water) Zone Heat – 3 Wires

No

Index

Page

Installation

2

Wiring Diagrams

3

Thermostat Quick Reference

4

Installer Confi guration Menu

4

Operation

6

Troubleshooting

7

Advertising