3.2.1.

Connecting to a Modem

When connecting directly to an external modem, use a standard

AT to Modem cable. Make certain the modem is initialized at

the same baud rate as the RPB+ (SetUp Switch 1). The modem

must be placed in Auto-Answer mode, and set to answer in one

ring. Please refer to the user’s guide for your external modem in

order to determine the appropriate AT command string.

3.3.

Power Connection

The Power Switch located on the back panel must be “On” in

order for the RPB+ to operate. Each time the unit is powered

On, the five AC outlets will be switched On or Off, as dictated

by the Power-Up Default String (see Section 4.1). Each outlet is

capable of switching up to 15 Amps of AC power. The total for

all 5 outlets cannot exceed 15 Amps.

Page 5

Installation

Figure 3: RS-232 (Control Port) Interface Schematic

Figure 4: RPB+ Cable Connections