Installation Instructions

975-0301-01-01

7

AC/DC Distribution Panel

The XADC may be pre-installed with an AC/DC Distribution Panel. The panel is
available in two configurations which provides the approved wiring boxes for AC
and DC connections:
30A (Part Number: 810-0030-00 XADC P30) – eight output breakers
50A (Part Number: 810-0050-00 XADC P50) – 10 output breakers
In each configuration there are also 11 unassigned DC fuses and four reserved
fuses for the battery connections.

Figure 3 and Figure 5 show the main components of the XADC with AC/DC
Distribution Panel.

Figure 2 XADC Internal Components

Item

Description

1

AC wiring compartment hole

2

Black AC line cable

3

White AC neutral cable

4

Green AC ground cable

5

Grommet (supplied)

6

Strain relief (not supplied)

7

DC wiring compartment hole ½ in. - 3/8 in. trade size (with ¾ in. knockout)

8

DC fuses

9

DC positive (+) and negative (-) connection lugs

POS

(+)

NEG

(-)

1

2

3

4

7

9

8

6

5

Important:

The XADC P30 and XADC P50 panels are not intended for use with rigid

conduit systems.