Clearances, Rear view, Air flow legend – York SUNLINE 2000 D2CG 072 User Manual

Page 14

Advertising
background image

DUCT COVERS - Units are shipped with all air duct
openings covered.
For side duct applications;
1. Remove and discard the supply and return air duct
covers.
2. Connect ductwork to duct flanges on the rear of the
unit.
For bottom duct applications;
1. Remove the side supply air duct cover to gain
access to the bottom supply air knockout panel.
2. Remove and discard the bottom knockout panel.
3. Replace the side duct cover.
4. With filter section access panel removed from the
unit, remove and discard the bottom return air
knockout panel.
5. Replace the filter access panel.

SCROLL COMPR.
ACCESS

11

1

2

4

5

8

3

7

7

8

6

1

2

17

1

2

11

1

2

17

1

2

REAR VIEW

SIDE SUPPLY AND RETURN

Front

32"

Back

12" (Less Economizer)
36" (With Economizer or Fixed
Air/Motorized Air Damper)

Left Side (Filter Access)

24" (Less Economizer)
36" (With Economizer)

Right Side (Cond. Coil)

24"

Below Unit

1

2

0"

Above Unit

2

72" (For Condenser Air Discharge)

1

Units may be installed on combustible floors made from wood or class A, B or C

roof covering material (Applicable in the U.S.A. only).

2

Units must be installed outdoors. Overhanging structures or shrubs should not

obstruct the outdoor coil nor the fan outlet.
NOTE: A 1" clearance must be provided between any combustible material and the
supply air ductwork for a distance of 3 feet from the unit.
The products of combustion must not be allowed to accumulate within a confined
space and recirculate.
Locate unit so that the vent air outlet hood is at least:

Three (3) feet above any forced air inlet located within 10 horizontal feet

(excluding those integral to the unit).

Four (4) feet below, 4 horizontal feet from, or 1 foot above any door or gravity air

inlet into the building.

Four (4) feet from electric meters, gas meters, regulators and relief equipment.

CLEARANCES

All dimensions are in inches. They are sub-
ject to change without notice. Certified di-
mensions will be provided upon request.

AIR FLOW LEGEND

RETURN AIR

SUPPLY AIR

OUTDOOR AIR

OUTDOOR AIR
(Economizer)

HOLE

KNOCKOUT

SIZE

(DIA.)

USED FOR

A

7/8" *

Control Wiring
(Side or Bottom)**

B

2" *

Power Wiring
(Side or Bottom)

C

1-5/8"

Gas Piping (Front)

D

1-1/2"

Gas Piping (Bottom)

*

Knockouts in the bottom of the unit can be located by the slice

in the insulation.

**

Do not remove the 2" knockout ring.

UTILITIES ENTRY DATA

FIG. 9 - DIMENSIONS AND CLEARANCE (3, 4, 5 & 6 TON)

(Direct-Drive Units)

UNIT WITH ECONOMIZER RAIN HOOD

44

7

8

B

30

7

8

"A"

10

1

4

4

3

8

A

3

1

2

8

1

4

19

1

8

44

7

8

19

1

2

27

1

2

19

3

4

3

4

“ CONDENSATE

DRAIN
(must be trapped)

DETAIL “A”

DETAIL “B”

DIMENSION "A"

FIXED

OUTDOOR

AIR DAMPER

12

MOTORIZED

DAMPER

16

1

2

UNIT WITH FIXED OUTDOOR

AIR/MOTORIZED DAMPER RAIN HOOD

530.18-N8Y

14

Unitary Products Group