Yamaha 01X User Manual

Page 146

Advertising
background image

Before Using

Basics Section

Appendix

Getting Started

Reference

146

01X Owner’s Manual

Troubleshooting

Pairing was specified, but the signal phase

does not match.

• Even when channels are paired,

the phase setting is not linked.

................................ page 102

Automation (Automix) cannot be stopped.

• Has the REMOTE AUTOMATION SETUP

parameter been set to correctly?

............................... page 88

Can’t use the internal effects.

• Effect BYPASS may be turned ON.

........................ page 102

• Are the level of STEREO IN 1, 2 faders raised?

........ page 99

• EFFECT PATCH may be set to

insertion (each channel).

......................................... page 102

• It is not possible to insert one effect

into multiple channels.

........................................... page 102

• 019. HQ. Pitch can be used only with EFFECT 1.

• When the sampling rate is 96kHz/88.2kH, only Effect 1 can be

used.

Can’t use SOLO.

• The channel may be set to Solo Safe.

........................ page 96

Fader groups and mute groups don’t work.

• In the Fader Group page and Mute Group page,

check that grouping is set to ENABLE.

.................. page 101

The pitch is wrong.

• Is the 01X operating on the same sampling frequency

as the synchronized external device?

......... page 92, “Connecting a Computer to an mLAN

device via mLAN” (Installation Guide), “mLAN Con-
nection Settings” (Graphic Patchbay Online Manual)

• Is the master device operating in a stable way?

• Is an effect such as HQ.Pitch or

Dual Pitch selected?

............................................... page 102

The layer of 17-24 (mLAN9-16) cannot be

used.

• When the sampling rate is set to 96kHz/88.2kHz,

the layer of 17 – 24 (mLAN) can not be selected.

..... page 40

Cannot edit with Studio Manager.

• Has the STUDIO MANAGER ID

been set correctly?

.................................................... page 94

• Is Port 4 (Studio Manager) selected for

Studio Manager data transmission/reception?

.......................... Studio Manager Owner’s Manual (PDF)

The Remote Control or Automation

features do not work.

• Is the correct DAW software selected in Remote Select?

........ page 87, “Demo playback/Remote Control Setup”

(Installation Guide)

• Are the mLAN settings correct?

.........“Demo playback/Remote Control Setup”

(Installation Guide)

• Are settings on the DAW correct?

.........page 87, “Demo playback/Remote Control Setup”

(Installation Guide)

• Is Port 1 selected for mLAN MIDI transmission/reception?

.........page 87, “Demo playback/Remote Control Setup”

(Installation Guide)

Cannot change the wordclock.

• Set this with the mLAN Auto Connector or

Graphic Patchbay when using mLAN.

.........“Connecting a Computer to an mLAN device via

mLAN” (Installation Guide), “Wordclock Settings”
(Graphic Patchbay Online Manual)

• Is the mLAN Auto Wordclock (AUTO W.CLK)

setting appropriate?

.........“Connecting a Computer to an mLAN device via

mLAN” (Installation Guide)

The mLAN connection does not work.

• Has the driver been installed?

.................... Installation Guide

• Is the mLAN cable properly connected? Check the connec-

tion; disconnect the mLAN cable once, then insert it again.

• (For Windows) Is mLAN set to “ON”? From the taskbar,

right click on the mLAN Manager icon.

.........“Confirming the installation” (Installation Guide)

• (For Windows) When adding a new IEEE 1394 card, right click

on the mLAN Manager icon in the taskbar and select “ON.”.

.........“Confirming the installation” (Installation Guide)

• Is the ACTIVE lamp on the rear panel of the 01X lit (in blue)?

If it is not lit, check the followings:

• In mLAN Driver Setup (from taskbar, right click on the mLAN

Manager icon, then “Driver Setup”), is the Status indicator
blue? If not, restart the 01X and re-enable connection by using
mLAN Auto Connector or Graphic Patchbay.

.........“Confirming the installation” (Installation Guide),

Graphic Patchbay Online Manual

• Is mLAN AUTO W.CLK (Auto Wordclock)

on the 01X set to “ENABLE”?

.........“Connecting a Computer to an mLAN device via

mLAN” (Installation Guide)

• Has connection been enabled with mLAN

Auto Connector or Graphic Patchbay?
Re-enable connection if necessary.

.........“Connecting the Computer and mLAN devices via

mLAN” (Installation Guide), “mLAN Connection
Settings” (Graphic Patchbay Online Manual)

• Have you changed the device? Even if the model is the same,

if the actual device is different, it is necessary to re-enable con-
nection by using mLAN Auto Connector or Graphic Patchbay.

.........“Connecting the Computer and mLAN devices via

mLAN” (Installation Guide), “mLAN Connection
Settings” (Graphic Patchbay Online Manual)

• Is there a loop connection? Check the cabling and make sure

none of the devices are connected in a loop.

Computer

Computer

01X

01X

: IEEE 1394-equipped device

Example of loop connection

Advertising