York PC9*DH User Manual

Page 6

Advertising
background image

246815-YTG-D-0108

6

Unitary Products Group

Thermostat Chart -

AC 26B

Two Stage Air Conditioner – Variable Speed Modulating Furnace

TWO STAGE

AIR

CONDITIONER

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

Y2

Second Stage

Compressor

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single Stage Compressor

VARIABLE SPEED

MODULATING

FURNACE CONTROL

G

Fan

VARIABLE SPEED

MODULATING

FURNACE

Y/Y2

Second or Full

Stage Compressor

HUM

Dehumidification-

Open on Humidity Rise

W

Modulating Heat

Part Numbers:

SAP = Legacy

171334 = 031-09153

1

1

Move HUMIDISTAT

jumper to “YES”

if humidistat is to be used.

FL9C

FC9C

PC9

ID MODELS

External Humidistat

(Optional)

Open on Humidity Rise

24VAC Humidifier

(Optional)

External Humidistat

(Optional)

Open on Humidity Rise

2

2

Part Number:

S1-2HU16700124

2

C

24 – Volt Common

R

24 – Volt Hot

Y

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*DN22C00124

THERMOSTAT

W2

Second Stage Heat

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

Y2

Second Stage

Compressor

G

Fan

*DP22U70124

THERMOSTAT

W2

Second Stage Heat

W

First Stage Heat

E/W1

First Stage Heat

Step 1 of Thermostat User

Configuration Menu must

be set to MS 2

Connection of the “C”

terminal, 24-Volt common

is optional when used with

batteries

Connection of the “C”

terminal, 24-Volt common

is optional when used with

batteries

Advertising