246815-YTG-D-0108

8

Unitary Products Group

Thermostat Chart -

O

Reversing Valve

Energized in Cool

C

24 – Volt Common

R

24 – Volt Hot

W1 OUT

First Stage Heat

W2 OUT

Second Stage Heat

Y2 OUT

Second Stage Compressor

Y1

Single Stage Compressor

X/L

Malfunction Light

Y2

Second Stage Compressor

W

Auxiliary Heat

BS

Bonnet Sensor

BSG

Bonnet Sensor

YORKGUARD VI

CONTROL

TWO STAGE

HEAT PUMP

Bonnet Sensor

(Optional)

C

24 – Volt Common

Y1

First Stage Compressor

L

Malfunction Light

Y2

Second Stage Compressor

G

Fan

*PP32U71124
*PP32U72124

THERMOSTAT

R

24 – Volt Hot

E/W1

First Stage Aux. Heat

W2

Second Stage Aux. Heat

DHM

Dehumidistat

HM

Humidistat

O

Reversing Valve

Energized in Cool

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single Stage Compressor

VARIABLE SPEED

MODULATING

FURNACE CONTROL

G

Fan

VARIABLE SPEED

MODULATING

FURNACE

Y/Y2

Second or Full

Stage Compressor

HUM

Dehumidification-

Open on Humidity Rise

W

Modulating Heat

Change FFuel jumper

on the heat pump control

to “ON”

1

Part Numbers:

SAP = Legacy

171334 = 031-09153

2

2

Move HUMIDISTAT

jumper to “YES”

if humidistat is to be used.

Part Numbers:

SAP = Legacy

126768 = 031-09137

18395 = 031-01996
340512 = 031-09178

1

FL9C

FC9C

PC9

ID MODELS

YZE

OD MODELS

YZH

H*5

H*8

Step 1 of the Thermostat

Installer Table must be

set to Heat Pump

E2/P Switch must be in the

E2 position

Step 2 of the Thermostat

Installer Table must be

set to 2

Step 5 of Thermostat User

Configuration Menu must

be set to “ON” for

Dehumidification

24VAC Humidifier

(Optional)

Change Hot Heat Pump

jumper on the heat pump

control to “ON”

HP 28A Two Stage Heat Pump – Variable Speed Modulating Furnace (With Hot Heat Pump Operation)