York PC9*DH User Manual

Page 9

Advertising
background image

246815-YTG-D-0108

Unitary Products Group

9

Thermostat Chart -

HP 28C

Two Stage Heat Pump – Variable Speed Modulating Furnace (With Hot Heat Pump Operation)

O

Reversing Valve

Energized in Cool

C

24 – Volt Common

R

24 – Volt Hot

W1 OUT

First Stage Heat

W2 OUT

Second Stage Heat

Y2 OUT

Second Stage Compressor

Y1

Single Stage Compressor

X/L

Malfunction Light

Y2

Second Stage Compressor

W

Auxiliary Heat

BS

Bonnet Sensor

BSG

Bonnet Sensor

YORKGUARD VI

CONTROL

TWO STAGE

HEAT PUMP

Bonnet Sensor

(Optional)

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single Stage Compressor

VARIABLE SPEED

MODULATING

FURNACE CONTROL

G

Fan

VARIABLE SPEED

MODULATING

FURNACE

Y/Y2

Second or Full

Stage Compressor

HUM

Dehumidification-

Open on Humidity Rise

W

Modulating Heat

Change FFuel jumper

on the heat pump control

to “ON”

1

Part Numbers:

SAP = Legacy

171334 = 031-09153

2

2

Move HUMIDISTAT

jumper to “YES”

if humidistat is to be used.

Part Numbers:

SAP = Legacy

126768 = 031-09137

18395 = 031-01996
340512 = 031-09178

1

FL9C

FC9C

PC9

ID MODELS

YZE

OD MODELS

YZH

H*5

H*8

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

O

Reversing Valve

Energized in Cool

L

Malfunction Light

Y2

Second Stage Compressor

G

Fan

*DN22H00124

*DP22U70124

THERMOSTAT

E/W1

First Stage Aux. Heat

W2

Second Stage Aux. Heat

C

24 – Volt Common

Y

First Stage Compressor

O/B

Reversing Valve

L

Malfunction Light

Y2

Second Stage Compressor

G

Fan

*PP32U70124

THERMOSTAT

E

Emergency Heat

R

24 – Volt Hot

(Heat XFMR)

RC

24 – Volt Hot
(Cool XFMR)

AUX

Auxiliary Heat

Step 1 of Thermostat

Installer/Configuration

Menu must be set to “HP2”

Selection of GAS/ELEC

switch on thermostat

not necessary

Thermostat Installer Setup

0170-System Type-

must be set to 12

3 Heat/2 Heat Pump

Thermostat Installer Setup

0190-Changeover Valve-

must be set to 0

O/B terminal

Energized in Cooling

Thermostat Installer Setup

0200-Backup Heat Source-

must be set to 1

Heat Pump Backup Heat

Source is Fossil Fuel

External Humidistat

(Optional)

Open on Humidity Rise

Thermostat Installer Setup

0210-External Fossil Fuel

Kit- must be set to 1

Heat Pump Control

is Controlling Heat Pump

Backup Heat

Change Hot Heat Pump

jumper on the heat pump

control to “ON”

3