036-21103-003 Rev. A (0403)

Unitary Products Group

3

1.

TXV = Thermal Expansion Valve kit required. Use 1TV700 series kit.

2.

Single phase units require single phase 2HK heaters — Three phase units require three phase 2HK heaters. (29) indicates 460 volt use only.

3.

G2FD coils available with a factory installed horizontal drain pan. Replace “S” with “H” in the model number.

— = Not Applicable.

Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 & 3 Phase

Additional R-22 Charge / Orifice Size for Various Matched Systems

Outdoor Unit (H1RA)

018S78

024S78

030S78

036S78

036S50

048S50

060S50

Unit Orifice(s)

1

51

57

69

71

71

84

Factory R-22 Charge, lbs-oz

3 - 13

3 - 14

3 - 14

4 - 11

4 - 11

7 - 10

9 - 12

Indoor Coil

Coil Orifice

2

System Orifice + Additional Charge, Oz

G2FD024S14,17

61

51

+

0

G2FD030S17

65

57

+

0

69

+

0

G2FD036S17

75

69 + 3

71 + 0

71 + 0

G2FD036S21

75

71

+

2

71

+

2

G2FD042S21

78

71

+

4

G2FD048S21,24

78

84

+

0

G2FD060S24

90

90

+

0

COOLING CAPACITY - With Air Handler Coils

UNIT MODEL

AIR HANDLER

COIL

3

MODEL

COOLING

MODEL

ELECTRIC

2

HEAT KW

W

RATED

CFM

NET MBH

KW

SEER SEER/TXV

1

EER

TOTAL SENS.

1 PHASE HRA / NAH

H1RA018S78

N1AHB1293

5,8,10,15,18

17

G2FD024S17

650

18.1

12.9

1.86

--

--

--

H1RA024S78

N1AHB1293

5,8,10,15,18

17

G2FD030S17

850

23.4

16.8

2.87

--

--

--

H1RA030S78

N1AHB1293

5,8,10,15,18

17

G2FD030S17

1000

28.9

20.0

3.45

--

--

--

N1AHB1293

5,8,10,15,18

17

G2FD036S17

1000

29.6

20.6

3.57

--

--

--

H1RA036S78

N1AHB1293

5,8,10,15,18

17

G2FD036S17

1250

33.5

25.2

3.83

--

--

--

3 PHASE HRA / NAH

H1RA036S50

N1AHB1293

5,8,10,15,18

17

G2FD036S17

1200

33.6

24.9

3.81

--

--

--

N1AHB1293

5,8,10,15,18

17

G2FD036S21

1200

34.4

25.5

3.87

N1AHC1693

5,8,10,15,20

21

G2FD042S21

1250

35.1

25.9

3.93

H1RA048S50

N1AHC1693

5,8,10,15,18

21

G2FD048S21

1600

48.8

35.9

4.82

--

--

--

H1RA060S50

N1AHD2093

5,8,10,15,18

24

G2FD060S24

1900

60.5

43.0

6.29

--

--

--

1 PHASE HRA / FRP (SINGLE PHASE)

H1RA018S78

F2RP024N93

5,7.5,10

18

--

650

18.1

12.9

1.86

--

--

--

H1RA024S78

F2RP024N93

5,7.5,10

18

--

850

23.4

16.8

2.87

--

--

--

H1RA030S78

F2RP036N93

5,7.5,10,15

21

--

1000

29.6

20.6

3.57

--

--

--

H1RA036S78

F2RP036N93

5,7.5,10,15

21

--

1250

34.3

25.6

3.86

--

--

--

3 PHASE HRA / FRP (SINGLE PHASE)

H1RA036S50

F2RP036N93

10,15

21

--

1200

34.4

25.5

3.87

--

--

--

H1RA048S50

F2RP048N93

10,15

24

--

1600

48.8

35.9

4.82

--

--

--

H1RA060S50

F2RP060N93

10,15

24

--

1900

60.5

43.0

6.29

--

--

--

Cooling MBH based on 8

0

°F entering air temperature, 50% RH, and rated air flow.

KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at
those conditions.

SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the
total electric power
input in watt-hours during the same period.