Ac switch (n.f.b.), Economy idle switch – Yamaha EF4000DE User Manual

Page 19

Advertising
background image

– 14 –

q

w

763-124a

240V

120V

120V

GR

779-017

W

X

G

Y

AE00863

AC SWITCH (N.F.B.)
The AC switch (Non-Fuse Breaker) turns off automati-
cally when the load exceeds the generator rated out-
put.

1

I “ON”

2

3 “OFF”

å EF4000DE/YG4000D
∫ EF5200DE/EF6600DE/YG5200D/YG6600D/YG6600DE

Supplies AC 120V (EF4000DE/YG4000D)
Supplies AC 120V (EF5200DE/EF6600DE/YG5200D/
YG6600D/YG6600DE)
Supplies AC 120V and 240V (EF4000DE/YG4000D)
Supplies AC 120V and 240V (EF5200DE/EF6600DE/
YG5200D/YG6600D/YG6600DE)

c

C

Reduce the load to the specified generator rated
output if the AC switch (N.F.B.) turns off. If it turns
off again, consult a Yamaha dealer.

D-2

D-1

C-2

C-1

AE00142

ECONOMY IDLE SWITCH
When the economy idle switch is turned to "ON", the
engine speed is automatically reduced to idle when
the generator load is reduced to 0.8 A or less. The
results are better fuel consumption and less noise.

1

I

“ON”

2

3 “OFF”

NOTE:

The economy idle switch must be turned to "OFF" to
increase engine speed to rated rpm when:

- using a load of 0.8 A or less.
- supplying AC 120V only from W with X.

q

w

763-193a

q

w

q

w

A

B

763-194d

q

w

w

q

C-1

C-2

763-195a

q

q

q

q

D-1

D-2

7WV-9-11 A 10/16/03 1:29 PM Page 14

Advertising
This manual is related to the following products: