– 41 –

762-003

AE00633

BATTERY
(for EF4000DE/EF5200DE/EF6600DE/YG6600DE)

1. Remove the battery.
2. Check the fluid level. Add only distilled water if

necessary. (See page 34; “BATTERY-
Replenishing the battery fluid”)

3. After checking the fluid level, charge the battery.
4. Store the battery in a cool, dark and dry place and

charge it once a month.

Do not store the battery in an excessively warm or
cold place [i.e., less than 0°C (30°F) or more than
30°C (90°F)].

w

9 Disconnect the negative lead first, then the

positive lead from the battery.

9 Connect the positive lead first, then the nega-

tive lead to the battery when installing the bat-
tery.

9 Never smoke or make and break connections

at the battery while charging. Sparks may
ignite the battery gas.

9 Be sure the battery terminals are tight and that

the battery vent tube is properly routed and is
securely attached to the battery.

c

C

9 Do not disconnect the battery during engine

operation.

9 Avoid operating the generator with the battery

removed.

AE00632

RECOMMENDED BATTERY
(for EF4000DE/EF5200DE/EF6600DE/YG6600DE)

NOTE:

9 Clamp the red wire to the positive (+) terminal and

the black wire to the negative (–) terminal of the
battery. Do not reverse these positions.

9 Be sure the battery is installed on the battery

mount tray securely.

Recommended battery:

Capacity: 12V/26A•h