b Command - 2D Bar Code - PDF417 Specific Options
Automatic PDF 417
Bar Code Generation
The printer automatically tests and changes the
PDF 417 bar code geometry to maximize the
readability of the bar code for a given maximum
height and width, specified by
p
4
and
p
5
.
The printer tests the PDF 417 parameters in this
order for a given data string (error correction
and compression included):
1. Module width
p
10
(for codeword width)
2. Symbol width
p
4
3. Symbol column maximum
p
13
4. Module height
p
11
5. Symbol height
p
5
6. Symbol row maximum
p
12
The printer will start with the maximum value
(default or explicit) for these parameters. The
printer reduces these values to get the module
width and height to maximize readability.