ZyWALL 5/35/70 Series User’s Guide

669

Appendix B Hardware Installation

Figure 414 Attaching Rubber Feet

Note: Do not block the ventilation holes. Leave space between ZyWALLs when

stacking.

Rack-mounted Installation Requirements

The ZyWALL can be mounted on an EIA standard size, 19-inch rack or in a wiring closet with
other equipment. Follow the steps below to mount your ZyWALL on a standard EIA rack
using a rack-mounting kit.

Note: Make sure the rack will safely support the combined weight of all the equipment

it contains.

Make sure the position of the ZyWALL does not make the rack unstable or top-
heavy. Take all necessary precautions to anchor the rack securely before
installing the unit.

Use a #2 Philips screwdriver to install the screws.

Note: Failure to use the proper screws may damage the unit.

Rack-Mounted Installation

1 Align one bracket with the holes on one side of the ZyWALL and secure it with the

bracket screws (smaller than the rack-mounting screws).

2 Attach the other bracket in a similar fashion.