ADPCM Card

ADPCM Card Error Messages

TC CGA

The Trunk Conditioning CGA setting identifies the type of trunk conditioning required for the
incoming circuit. If v&s is chosen in the Type setting, the options are idle or busy. If trnsp or
v is chosen as the Type, the only option is n/a.

If this engine is assigned to a voice card, this selection will show the value you selected on the
voice card port. If assigned to an SRU or BRI card port, the field will show n/a. It cannot be
changed from this screen.

1.4

ADPCM Card Error Messages

Refer to Appendix B in the System Reference Guide for further information on Error
Messages regarding this card.

1.5

ADPCM Card Troubleshooting

The following are instructions on how to troubleshoot the ADPCM card. This is in case the
card fails for any reason:

1. Green LED on faceplate.

2. Verify that the card is in the right slot, P1 through P3.

3. Reseat the card if necessary. This can be done with the power on.

4. View the card status on the main screen.

5. Check the cards configuration options. Select the card from the main screen to do this.

6. Now try to log into the ADPCM main screen. If this still didn’t work the card may be

bad. Try swapping it with a new card.

7. If the ADPCM card is determined to be faulty, replace it and return the faulty unit for

repair to the location specified by your distributor.