York THGD18 THRU 60 User Manual

Page 11

Advertising
background image

365147-YTG-C-0608

Johnson Controls Unitary Products

11

CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.
— = Not Applicable.

13 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED

THGD18S21S1

AV24

–

17.0 3.46 1.40 9.0 2.32 1.08 8.00

THGD24S21S1

AV24

–

22.0 4.04 1.62 12.0 2.64 1.28 8.40

THGD30S21S1

AV36

–

28.0 3.80 2.18 14.0 2.38 1.76 8.00

THGD36S21S1

AV36

–

33.0 3.74 2.61 20.0 2.62 2.23 8.80

AV/SV48

–

33.0 3.74 2.61 20.0 2.62 2.23 8.80

THGD42S21S1

AV/SV48

–

40.0 3.68 3.18 24.0 2.74 2.58 8.85

AV/SV60

–

40.0 3.70 3.20 24.0 2.74 2.58 8.85

F4FV060

–

40.0 3.70 3.20 24.0 2.74 2.58 8.85

THGD48S21S1

AV/SV48

–

48.0 3.50 3.97 37.0 2.82 3.84 8.00

AV/SV60

–

48.0 3.48 3.99 37.0 2.82 3.84 8.00

F4FV060

–

48.0 3.48 3.99 37.0 2.82 3.84 8.00

13 SEER HP WITH AHP / SHP / F*FP

THGD18S21S1

AHP18

–

17.0 3.26 1.54 9.0 2.18 1.23 7.70

AHP24

–

17.0 3.28 1.52 9.0 2.18 1.22 7.70

F4FP024

–

17.0 3.26 1.54 9.0 2.18 1.23 7.70

THGD24S21S1

AHP24

–

23.0 3.74 1.80 12.0 2.46 1.45 7.70

AHP30

–

23.0 3.74 1.80 12.0 2.44 1.46 7.70

F4FP030

–

23.0 3.74 1.80 12.0 2.46 1.45 7.70

THGD30S21S1

AHP30

–

29.0 3.54 2.41 15.0 2.24 1.96 7.65

AHP36

–

29.0 3.54 2.41 15.0 2.24 1.96 7.65

F4FP040

–

29.0 3.54 2.41 15.0 2.24 1.96 7.65

THGD36S21S1

AHP36

–

34.0 3.58 2.78 21.0 2.52 2.39 8.50

AHP42

–

34.0 3.60 2.76 20.0 2.52 2.37 8.55

AHP/SHP60

–

33.0 3.74 2.61 20.0 2.62 2.23 8.80

F4FP045

–

34.0 3.58 2.78 21.0 2.52 2.39 8.50

F5FP048

–

33.0 3.74 2.61 20.0 2.62 2.23 8.80

F5FP060

–

33.0 3.74 2.61 20.0 2.62 2.23 8.80

THGD42S21S1

AHP/SHP48

–

42.0 3.56 3.41 25.0 2.64 2.75 8.60

AHP/SHP60

–

40.0 3.70 3.20 24.0 2.74 2.58 8.85

F4FP045

–

42.0 3.56 3.41 25.0 2.64 2.75 8.60

F5FP048

–

40.0 3.70 3.20 24.0 2.74 2.58 8.85

F5FP060

–

40.0 3.70 3.20 24.0 2.74 2.58 8.85

THGD48S21S1

AHP/SHP48

–

48.0 3.40 4.13 37.0 2.74 3.99 7.70

AHP/SHP60

–

48.0 3.48 3.99 37.0 2.80 3.87 8.00

F5FP060

–

48.0 3.48 3.99 37.0 2.80 3.87 8.00

1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and

no supplemental electric heat operation.

HEATING PERFORMANCE - With Air Handler (Continued)

UNIT

MODEL*

AIR

HANDLER

COIL

1

MODEL

ARI HEATING

2

47

°F

17

°F

HSPF

MBH

COP

KW

MBH

COP

KW

STD