Conversion from natural gas to lpg – Zanussi ZGF 782 User Manual

Page 19

Advertising
background image

19

Conversion from Natural Gas to LPG

It is important to note that this model is designed for

use with natural gas but can be converted for use

with butane or propane gas providing the correct

injectors are fitted. The gas rate is adjusted to suit.

Method

• Ensure that the gas taps are in the 'OFF' position

• Isolate the hob from the electrical supply

• Remove all pan supports, burner caps, rings, crowns

and control knobs.

• With the aid of a 7mm box spanner the burner

injectors can then be unscrewed and replaced by

the appropriate LPG injectors.

TO ADJUST THE GAS RATE

With the aid of a thin bladed screwdriver completely

tighten down the by pass adjustment screw, which is

located down the centre of the gas tap control shaft.

Upon completion stick the replacement rating plate on

the under side of the hob.

IMPORTANT

The replacement/conversion of the gas hob should

only be undertaken by a competent person.

Advertising