Table 4.3, For det – Xantrex Technology XPR 150-40 User Manual

Page 65

Advertising
background image

Remote Operation

Select Remote Control Function

Release 1.1

63

Table 4.3 Power Supply Settings for Different Programming Sources

Note: The front panel RMT/LCL switch may be pressed at any time, to force both the voltage and
current setpoints to be remotely controlled via the J1 inputs.

Power Supply Output Current Limit: Programming Source

0-5 Vdc

0-10 Vdc

0-5 k Resistor

0-10 k Resistor

None (Front

Panel Control:

Local Mode)

S1-1=

OFF

S1-1=

OFF

S1-1=

OFF

S1-1=

OFF

S1-1=

OFF

S1-2=

OFF

S1-2=

OFF

S1-2=ON

S1-2=ON

S1-2=

OFF

S1-3=

OFF

S1-3=

OFF

S1-3=

OFF

S1-3=

OFF

S1-3=

OFF

S1-4=

OFF

S1-4=ON

S1-4=

OFF

S1-4=ON

S1-4=

OFF

S1-5=ON

S1-5=ON

S1-5=ON

S1-5=ON

S1-5=ON

S1-6=ON

S1-6=ON

S1-6=ON

S1-6=ON

S1-6=

OFF

S1-1=

OFF

S1-1=

OFF

S1-1=

OFF

S1-1=

OFF

S1-1=

OFF

S1-2=

OFF

S1-2=

OFF

S1-2=ON

S1-2=ON

S1-2=

OFF

S1-3=ON

S1-3=ON

S1-3=ON

S1-3=ON

S1-3=ON

S1-4=

OFF

S1-4=ON

S1-4=

OFF

S1-4=ON

S1-4=ON

S1-5=ON

S1-5=ON

S1-5=ON

S1-5=ON

S1-5=ON

S1-6=ON

S1-6=ON

S1-6=ON

S1-6=ON

S1-6=

OFF

S1-1=ON

S1-1=ON

S1-1=ON

S1-1=ON

S1-1=ON

S1-2=

OFF

S1-2=

OFF

S1-2=ON

S1-2=ON

S1-2=

OFF

S1-3=

OFF

S1-3=

OFF

S1-3=

OFF

S1-3=

OFF

S1-3=

OFF

S1-4=

OFF

S1-4=ON

S1-4=

OFF

S1-4=ON

S1-4=

OFF

S1-5=ON

S1-5=ON

S1-5=ON

S1-5=ON

S1-5=ON

S1-6=ON

S1-6=ON

S1-6=ON

S1-6=ON

S1-6=

OFF

S1-1=ON

S1-1=ON

S1-1=ON

S1-1=ON

S1-1=ON

S1-2=

OFF

S1-2=

OFF

S1-2=ON

S1-2=ON

S1-2=

OFF

S1-3=ON

S1-3=ON

S1-3=ON

S1-3=ON

S1-3=ON

S1-4=

OFF

S1-4=ON

S1-4=

OFF

S1-4=ON

S1-4=ON

S1-5=ON

S1-5=ON

S1-5=ON

S1-5=ON

S1-5=ON

S1-6=ON

S1-6=ON

S1-6=ON

S1-6=ON

S1-6=

OFF

S1-1=

OFF

S1-1=

OFF

S1-1=

OFF

S1-1=

OFF

S1-1=

OFF

S1-2=

OFF

S1-2=

OFF

S1-2=ON

S1-2=ON

S1-2=

OFF

S1-3=

OFF

S1-3=ON

S1-3=

OFF

S1-3=ON

S1-3=ON

S1-4=

OFF

S1-4=ON

S1-4=

OFF

S1-4=ON

S1-4=ON

S1-5=

OFF

S1-5=

OFF

S1-5=

OFF

S1-5=

OFF

S1-5=

OFF

S1-6=ON

S1-6=ON

S1-6=ON

S1-6=ON

S1-6=

OFF

!

CAUTION
To prevent possible damage, the power supply settings for different sources must be strictly used as

shown in Table 4.3, “Power Supply Settings for Different Programming Sources,” on page 63.

Po

we

r Sup

p

ly

Ou

tpu

t

V

o

lt

ag

e: Pr

og

ramm

in

g Sou

rc

e

0-5

V

dc

0-1

0

Vd

c

0-5

k Resistor

0-10

k Resi

stor

N

one (Fro

nt

Pan

el

C

ontrol: L

ocal

Mode)

Default settings

Advertising
This manual is related to the following products: