Table a.2 – Xantrex Technology XPR 150-40 User Manual

Page 69

Advertising
background image

Specifications and Characteristics

Electrical Specifications—Summary

Release 1.1

67

Table A.2Drift Specifications for 6000 Watt units (10V to 60V Models)

Models

10–600

20–300

30–200

40–150

60–100

Drift (30 minutes):

1

Voltage (0.04% of Vmax)
Current (0.6% of Imax)

1. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.

4 mV
3600 mA

8 mV
1800 mA

12 mV
1200 mA

16 mV
900 mA

24 mV
600 mA

Drift (8 hours):

2

Voltage (0.02% of Vmax)
Current (0.04% of Imax)

2. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.

2 mV
240 mA

4 mV
120 mA

6 mV
80 mA

8 mV
60 mA

12 mV
40 mA

Temperature Coefficient:

3

Voltage (0.04% of Vmax/°C)
Current (0.06% of Imax/°C)

3. Change in output per

°C change in ambient temperature, with constant line and load.

4 mV
360 mA

8 mV
180 mA

12 mV
120 mA

16 mV
90 mA

24 mV
60 mA

Advertising
This manual is related to the following products: