Table 6: cooling capacities - 4 ton (dee / deg048), 6 cooling capacities - 4 ton (dee / deg048), Nominal rating all sensible capacity – York SUNLINE PLUS D1EE036 User Manual

Page 9

Advertising
background image

036-21411-002-A-0204

Unitary Products Group

9

TABLE 6: COOLING CAPACITIES - 4 TON (DEE / DEG048)

AIR ON

EVAPORATOR

COIL

TEMPERATURE OF AIR ON CONDENSER COIL

85°F

95°F

TOTAL

CAP.

1

MBH

POWER

INPUT

2

kW

SENSIBLE CAPACITY

1

, MBH

TOTAL

CAP

.1

MBH

POWER

INPUT

2

kW.

SENSIBLE CAPACITY

1

, MBH

ENTERING DRY BULB, °F

ENTERING DRY BULB, °F

CFM

WB

°F

86

83

80

77

74

71

68

86

83

80

77

74

71

68

2000

72

64

3.9

45

39

33

27

21

-

-

60

4.2

44

38

32

26

20

-

-

67

57

3.8

55

49

43

37

31

25

19

53

4.1

53

47

41

35

29

23

17

62

54

3.8

54

54

53

47

41

35

29

50

4.0

50

50

50

44

38

32

26

57

54

3.8

54

54

54

48

42

36

30

50

4.0

50

50

50

46

40

34

28

1800

72

62

3.9

42

36

31

25

20

-

-

58

4.2

41

35

30

24

19

-

-

67

55

3.8

51

46

40

35

30

24

19

52

4.1

50

44

39

34

28

23

18

62

52

3.8

52

52

49

44

39

33

28

49

4.1

49

49

47

42

37

31

26

57

52

3.8

52

52

51

45

40

35

29

49

4.1

49

49

49

44

38

33

27

1600

72

59

3.9

38

33

29

24

19

-

-

57

4.2

38

33

28

23

18

-

-

67

54

3.8

48

43

38

33

29

24

19

52

4.2

47

42

37

32

28

23

18

62

50

3.7

50

50

46

41

36

32

27

47

4.1

47

47

45

40

35

31

26

57

50

3.7

50

50

47

42

38

33

28

47

4.1

47

47

46

41

37

32

27

1400

72

58

3.8

35

31

27

23

18

-

-

55

4.2

34

30

26

22

17

-

-

67

52

3.8

44

39

35

31

27

22

18

49

4.2

42

38

34

30

26

21

17

62

49

3.7

48

47

43

39

34

30

26

46

4.1

46

45

42

37

33

29

25

57

49

3.7

49

48

44

40

36

31

27

46

4.1

46

46

43

38

34

30

26

1200

72

57

3.8

32

29

25

21

17

-

-

53

4.2

31

28

24

20

16

-

-

67

50

3.8

40

36

32

29

25

21

17

47

4.2

38

35

31

27

23

20

16

62

48

3.7

47

44

40

36

33

29

25

45

4.1

45

42

38

34

31

27

23

57

48

3.7

48

45

41

37

34

30

26

45

4.1

45

43

39

35

32

28

24

AIR ON

EVAPORATOR

COIL

TEMPERATURE OF AIR ON CONDENSER COIL

105°F

115°F

TOTAL

CAP

.1

MBH

POWER

INPUT

2

kW.

SENSIBLE CAPACITY

1

, MBH

TOTAL

CAP

.1

MBH

POWER

INPUT

2

kW.

SENSIBLE CAPACITY

1

, MBH

ENTERING DRY BULB, °F

ENTERING DRY BULB, °F

CFM

WB

°F

86

83

80

77

74

71

68

86

83

80

77

74

71

68

2000

72

56

4.7

42

36

30

25

19

-

-

53

5.2

41

35

29

23

17

-

-

67

50

4.6

50

45

39

33

28

22

16

47

5.1

47

44

38

32

26

20

14

62

47

4.5

47

47

47

41

35

29

23

44

5.0

44

44

44

38

32

26

20

57

47

4.5

47

47

47

44

38

32

26

44

5.0

44

44

44

42

36

30

24

1800

72

54

4.7

39

34

29

23

17

-

-

51

5.1

38

33

27

22

17

-

-

67

49

4.6

47

43

37

32

27

21

16

46

5.1

45

41

36

31

25

20

14

62

46

4.5

46

46

45

40

34

29

23

43

5.0

43

43

43

37

32

26

21

57

46

4.5

46

46

46

42

36

31

26

43

5.0

43

43

43

40

34

29

24

1600

72

53

4.7

36

31

27

22

17

-

-

49

5.1

35

30

25

21

16

-

-

67

48

4.6

45

40

35

31

26

21

16

44

5.1

43

39

34

29

24

19

15

62

44

4.6

44

44

43

38

33

29

24

41

5.0

41

41

41

36

31

26

22

57

44

4.5

44

44

44

39

34

30

25

41

5.0

41

41

41

37

32

28

23

1400

72

51

4.7

33

29

25

21

16

-

-

48

5.1

32

28

24

20

15

-

-

67

46

4.6

41

37

33

28

24

20

16

43

5.0

40

35

31

27

23

19

14

62

43

4.5

43

42

40

36

31

27

23

40

5.0

40

40

38

34

30

25

21

57

43

4.5

43

43

41

37

32

28

24

40

5.0

40

40

39

35

31

26

22

1200

72

50

4.7

30

27

23

19

16

-

-

47

5.1

30

26

22

18

15

-

-

67

44

4.6

37

33

30

26

22

19

15

42

5.0

36

32

29

25

21

18

14

62

42

4.5

42

41

37

33

29

26

22

39

5.0

39

39

35

32

28

24

21

57

42

4.5

42

41

38

34

30

27

23

39

5.0

39

39

36

33

29

25

22

1.

These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from Table 9 or 11, multiply
this value by 3.425 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit.

2.

These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan
motor power input is 0.36kW. Refer to Tables 9 or 11 for the kW of the supply air blower motor.

NOMINAL RATING

ALL SENSIBLE CAPACITY

Advertising
This manual is related to the following products: