Freedom 10 power switch, Remote control panel, Freedom 10 – Xantrex Technology 10 User Manual

Page 40: Remote control panel –2, 12 v models –2, 12 v models

Advertising
background image

Operation

3–2

975-0251-01-01

Freedom 10 Power Switch

The power switch is located on the front panel of the Freedom 10. This switch
controls

ON

/

OFF

and

RESET

for the inverter. Expect a 3-second delay when the

power switch is turned

ON

before the unit is activated.

If installed with the remote control panel, the power switch on the unit itself
should be left in the

OFF

position.

If the unit is connected to external AC power, the power switch may be turned off,
but the battery charger will continue to function. The internal transfer switch will
continue to be engaged with the switch off and AC power will be available at the
output of the unit. If AC power is removed, the unit will not come on as an
inverter.

Remote Control Panel

12 V Models

The remote control panel provides LED bar graphs that show system status,
battery voltage, and current in both inverter and charge modes. For more
information about this remote, refer to its owner’s manual.

Figure 3-1 Freedom 10 Power Switch

Important:

The power switch controls the inverter function. Placing the switch in the

OFF

position disables the inverter and connects mains to the output.

Figure 3-2 Remote Control Panel For 12 V Models

Advertising