Remote Control Panel

975-0251-01-01

3–3

24 V Models

This section contains information about the remote control panel for 24 V models.
The remote control panel provides LED bar graphs that show system status,
battery voltage, and current in both inverter and charge modes. These bar graphs
can also display DIP switch positions and shutdown conditions.

Power Switch

The switch on the remote is used to control the inverter and can be used to control
the battery charger function also. When a remote control is used, the power switch
on the unit itself should be left in the

OFF

position.

System Status LEDs

These four LEDs monitor the system as described in Table 3-1.

Figure 3-3 Remote Control Panel for 24 V Models

Table 3-1 System Status LED summary

Status LED

Appearance Purpose

BATTERY

On Steady

This is a warning condition.
Inverter mode: Battery > 30.5 or < 21 volts
Charger mode: Battery > 30.5 or < 20 volts.

BATTERY

Blinking

Indicates either a shutdown or equalizing.
Battery > 31 volts will automatically reset at 30.5.
Inverter mode: Battery < 20 volts, will
automatically reset at charger float voltage or upon
AC input.
Charger mode: Battery < 16 volts for 1 minute,
remove all DC loads and manually reset by cycling
the power switch.

OVERLOAD

On Steady

Indicates an over-temperature condition, the unit is
shut down.

Advertising