York 251934-YTG-J-0910 User Manual

Page 42

Advertising
background image

251934-YTG-J-0910

42

Johnson Controls Unitary Products

115°F

125°F

3750

77

182.9

17.2

76.5

65.8

49.1

-

-

-

168.9

19.0

74.3

63.9

47.1

-

-

-

72

166.4

17.0

108.9

92.2

75.5

58.8

-

-

153.5

18.6

106.2

89.4

72.6

55.9

-

-

67

149.8

16.8

141.2

118.6

101.9

85.2

68.5

-

138.0

18.3

138.0

114.9

98.2

81.4

64.6

-

62

137.8

16.6

137.8

130.9

108.7

92.0

75.3

58.6

127.1

18.1

127.1

117.2

96.9

80.1

63.4

46.6

4500

77

188.9

17.2

91.3

72.5

53.7

-

-

-

173.9

19.0

91.3

70.1

51.3

-

-

-

72

171.8

17.0

120.1

101.3

82.5

63.7

-

-

158.0

18.6

116.7

97.9

79.1

60.3

-

-

67

154.7

16.8

149.0

130.2

111.4

92.6

73.8

-

142.1

18.3

142.1

125.7

106.9

88.1

69.3

-

62

142.3

16.6

142.3

137.7

118.9

100.1

81.3

62.5

130.8

18.1

130.8

124.3

105.5

86.7

67.8

49.0

57

148.1

16.7

148.1

148.1

131.4

112.6

93.8

75.0

138.6

18.2

138.6

138.6

123.3

104.5

85.7

66.9

5250

77

194.9

17.3

106.1

79.2

58.3

-

-

-

178.9

19.0

108.3

76.3

55.5

-

-

-

72

177.3

17.1

131.4

110.5

89.6

68.7

-

-

162.6

18.6

127.3

106.4

85.6

64.8

-

-

67

159.7

16.8

156.8

141.9

121.0

100.1

79.1

-

146.2

18.3

146.2

136.5

115.7

94.9

74.0

-

62

146.9

16.7

146.9

144.6

129.1

108.2

87.3

66.4

134.6

18.1

134.6

131.3

114.0

93.2

72.3

51.5

57

152.8

16.7

152.8

152.8

142.7

121.7

100.8

79.9

142.7

18.2

142.7

142.7

133.3

112.5

91.7

70.8

6000

77

201.0

17.3

120.9

85.9

62.9

-

-

-

184.0

19.0

125.2

82.6

59.7

-

-

-

72

182.8

17.1

142.7

119.7

96.7

73.7

-

-

167.2

18.6

137.8

114.9

92.1

69.2

-

-

67

164.6

16.9

164.6

153.5

130.5

107.5

84.5

-

150.4

18.3

150.4

147.3

124.4

101.6

78.7

-

62

151.4

16.7

151.4

151.4

139.3

116.3

93.2

70.2

138.4

18.1

138.4

138.4

122.5

99.7

76.8

53.9

57

157.5

16.8

157.5

157.5

153.9

130.9

107.9

84.9

146.7

18.2

146.7

146.7

143.4

120.5

97.7

74.8

6750

72

184.3

17.1

153.1

128.5

104.0

79.5

-

-

168.5

18.7

147.1

122.8

98.6

74.3

-

-

67

166.0

16.9

166.0

160.5

140.4

115.9

91.4

-

151.6

18.3

151.6

150.8

133.2

108.9

84.7

-

62

152.7

16.7

152.7

152.7

146.6

122.1

97.6

73.0

139.5

18.1

139.5

139.5

131.6

107.3

83.0

58.7

57

158.9

16.8

158.9

158.9

157.1

132.5

108.0

83.5

147.9

18.3

147.9

147.9

146.2

121.9

97.7

73.4

7500

72

185.9

17.2

163.4

137.4

111.3

85.3

-

-

169.8

18.7

156.5

130.8

105.0

79.3

-

-

67

167.4

17.0

167.4

167.4

150.3

124.3

98.2

-

152.8

18.4

152.8

152.8

142.0

116.3

90.6

-

62

154.0

16.8

154.0

154.0

154.0

127.9

101.9

75.9

140.6

18.2

140.6

140.6

140.6

114.9

89.2

63.5

57

160.2

16.9

160.2

160.2

160.2

134.2

108.1

82.1

149.0

18.3

149.0

149.0

149.0

123.3

97.6

71.9

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower

Performance Table for the kW of the supply air blower motor.

2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

ZF180 (15 Ton) (Continued)

Air on

Evaporator Coil

Temperature of Air on Condenser Coil

Total

Capacity

1

(MBh)

Total
Input

(kW)

2

Sensible Capacity (MBh)

Total

Capacity

1

(MBh)

Total
Input

(kW)

2

Sensible Capacity (MBh)

CFM

WB
(°F)

Return Dry Bulb (°F)

Return Dry Bulb (°F)

90

85

80

75

70

65

90

85

80

75

70

65

Advertising