Multipliers for determining the performance with other indoor sections.

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

HIGH CFM

HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION

OUTDOOR UNIT MODEL NO.

YZE03611

INDOOR COIL MODEL NO.

FC/MC/PC48C + MV16C

AIR TEMP.

ENTERING
OUTDOOR

UNIT

AIR TEMP.

ENTERING

INDOOR

COIL

ID CFM

1100

1200

1300

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

60

60

37.7 2.6 4.3 38.4 2.5 4.5 39.1 2.4 4.7

70

36.7 2.8 3.8 37.2 2.7 4.0 37.8 2.7 4.1

80

35.7 3.0 3.4 36.0 3.0 3.6 36.5 2.9 3.7

47

60

34.5 2.4 4.2 34.3 2.4 4.3 34.2 2.3 4.3

70

32.9 2.7 3.6 33.0 2.6 3.7 33.2 2.6 3.8

80

31.3 2.9 3.1 31.7 2.9 3.2 32.1 2.8 3.3

40

60

30.4 2.3 3.8 30.7 2.3 3.9 31.0 2.3 4.0

70

29.3 2.6 3.3 29.8 2.5 3.4 30.4 2.5 3.5

80

28.3 2.9 2.9 29.0 2.8 3.0 29.7 2.8 3.1

30

60

25.6 2.2 3.4 24.6 2.1 3.4 23.7 2.0 3.4

70

25.7 2.5 3.0 25.1 2.4 3.0 24.5 2.4 3.0

80

25.9 2.8 2.7 25.6 2.7 2.8 25.3 2.7 2.8

17

60

20.8 2.1 2.9 20.9 2.1 2.9 21.0 2.1 2.9

70

19.9 2.3 2.5 20.8 2.4 2.6 21.8 2.4 2.7

80

18.9 2.6 2.2 20.7 2.6 2.3 22.6 2.7 2.5

10

60

19.3 2.1 2.7 19.7 2.1 2.7 20.1 2.1 2.8

70

17.9 2.4 2.2 19.1 2.4 2.4 20.3 2.4 2.5

80

16.4 2.6 1.9 18.5 2.6 2.1 20.5 2.6 2.3

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Air Handler

Coil

MBH

KW

COP

AV36

1.00 1.00 1.00

AV48

1.01 1.00 1.01

MV12B

FC/MC35B

1.00 1.00 1.00

MV12B

FC/MC42B

1.00 1.00 1.00

MV16C

FC/MC48C

1.00 1.00 1.00

MV12D

FC/MC48D

1.00 1.00 1.00

Variable Speed
Furnace

Coil

T.C.

S.C.

KW

P(C,V)9*B12

FC/MC/PC35B

1.00 1.00 1.00

PV8*B16

FC/MC/PC35B

1.00 0.99 1.01

P(C,V)9*C16

FC/MC/PC35C

1.00 1.00 1.00

PV8*C16

FC/MC/PC35C

1.00 1.00 1.00

PV8*C20

FC/MC/PC35C

1.00 0.99 1.01

P(C,V)9*C20

FC/MC/PC35C

1.00 0.99 1.01

PV8*B16

FC/MC/PC42B

1.00 1.00 1.00

P(C,V)9*B12

FC/MC/PC42B

1.00 1.00 1.00

P(C,V)9*C20

FC/MC/PC42C

1.00 1.00 1.00

P(C,V)9*C16

FC/MC/PC42C

1.00 1.00 1.00

PV8*C16

FC/MC/PC42C

1.00 1.01 0.99

PV8*C20

FC/MC/PC42C

1.00 1.00 1.00

P(C,V)9*C20

FC/MC/PC48C

1.00 1.00 1.00

P(C,V)9*C16

FC/MC/PC48C

1.00 1.00 1.00

PV8*C16

FC/MC/PC48C

1.00 1.00 1.00

PV8*C20

FC/MC/PC48C

1.00 1.00 1.00

P(C,V)9*D20

FC/MC/PC48D

1.00 1.00 1.00

PV8*C16

HC42

1.00 1.00 1.00

PV8*C20

HC42

1.00 1.00 1.00

PV8*B16

UC42B

1.00 1.00 1.00

P(C,V)9*B12

UC42B

1.00 1.00 1.00

PV8*C20

UC42C

1.00 1.00 1.00

PV8*C16

UC42C

1.00 1.00 1.00

P(C,V)9*C16

UC42C

1.00 1.00 1.00

P(C,V)9*C20

UC42C

1.00 1.00 1.00

P(C,V)9*C20

UC48C

1.00 1.00 1.00

PV8*C20

UC48C

1.00 1.00 1.00

PV8*C16

UC48C

1.00 1.00 1.00

P(C,V)9*C16

UC48C

1.00 1.00 1.00

P(C,V)9*D20

UC48D

1.00 1.00 1.00

Variable Speed
Furnace

Coil

T.C.

S.C.

KW