Introduction

1–4

975-0337-01-01

Low voltage shutdown

The inverter shuts off when your batteries reach a predetermined
voltage set in the microprocessor to protect batteries from permanent
damage. Low voltage shutdown also monitors frequency and voltage,
and protects against overload, short circuits and over-temperature.

Automatic shutdown after 8 hours for loads less than 15 ±5 watts

This feature prevents the inverter from draining the batteries if it is
left on without a load.

Charger
features

The IP1012 AL offers the following charger features:

3-stage charging with 50 amps maximum charging current for 12V
battery type when shorepower is connected, to ensure your batteries
are always charged

Automatic transfer to invert mode

When the AC shorepower cord is disconnected, the unit automatically
switches to invert mode. When AC shorepower is available again, the
inverter automatically switches to charging/pass-through mode.

Load management capability which temporarily reduces charging
current to the batteries when a large AC load is applied to the inverter
output. This capability helps reduce the chance of tripping the
shorepower breaker.